Measuring Arterial Oxygen Saturation Using Wearable Devices Under Varying Conditions

Author:

Hearn Eleanor L.,Byford Jack,Wolfe Christopher,Agyei Cheryl,Hodkinson Peter D.,Pollock Ross D.,Smith Thomas G.

Abstract

INTRODUCTION: Recently developed wearable monitoring devices can provide arterial oxygen saturation (Spo2) measurements, offering potential for use in aerospace operations. Pilots and passengers are already using these technologies, but their performance has not yet been established under conditions experienced in the flight environment such as environmental hypoxia and concurrent body motion.METHODS: An initial evaluation was conducted in 10 healthy subjects who were studied in a normobaric chamber during normoxia and at a simulated altitude of 15,000 ft (4572 m; 11.8% oxygen). Spo2 was measured simultaneously using a standard pulse oximeter and four wearable devices: Apple Watch Series 6; Garmin Fēnix 6 watch; Cosinusso Two in-ear sensor; and Oxitone 1000M wrist-worn pulse oximeter. Measurements were made while stationary at rest, during very slight body motion (induced by very low intensity cycling at 30 W on an ergometer), and during moderate body motion (induced by moderate intensity cycling at 150 W).RESULTS: Missed readings, defined as failure to record an Spo2 value within 1 min, occurred commonly with all wearables. Even with only very slight body motion, most devices missed most readings (range of 12–82% missed readings) and the rate was higher with greater body motion (range 18–92%). One device tended to under-report Spo2, while the other devices tended to over-report Spo2. Performance decreased across the devices when oxygenation was reduced.DISCUSSION: In this preliminary evaluation, the wearable devices studied did not perform to the same standard as a traditional pulse oximeter. These limitations may restrict their utility in flight and require further investigation.Hearn EL, Byford J, Wolfe C, Agyei C, Hodkinson PD, Pollock RD, Smith TG. Measuring arterial oxygen saturation using wearable devices under varying conditions. Aerosp Med Hum Perform. 2023; 94(1):42–47.

Publisher

Aerospace Medical Association

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3