Anthropometric Measurements Of The Ventrogluteal İnjectıon Area: A Cross-sectional Study

Author:

Tuğrul EmelORCID,Khorshıd Leyla,Tunçyürek Özüm

Abstract

Research Problem / Aim: The ventrogluteal injection area is one of the areas most frequently used by nurses in intramuscular injection applications. The thicknesses of the subcutaneous tissue and the muscle tissue in this area are important for a safe injection. The aim of this study is the determination of the subcutaneous and muscle tissue thicknesses on the ventrogluteal injection area and the anthropometric data about it. Method: The study has designed a cross-sectional study. 150 individuals who applied to the ultrasound unit of the hospital and accepted to participate in the study were included in the study. The ventrogluteal injection area was determined with the ‘’V’’ method by the researcher. The subcutaneous and muscle tissue thicknesses from the areas on the injection area and the areas 2 and 4 cm around the injection area were determined using the ultrasound device. Moreover, the relation between the anthropometric measurements of the individuals (height, weight, waist, hip and crista iliaca circumferences, distance between the large trochanter and crista iliaca and crista iliaca anterior) and the tissue thicknesses on the injection area were evaluated. The data of the research were evaluated with definitive statistics, ANOVA test and posthoc Tukey test, t test and correlation analysis. The p<0.05 value was accepted as statistically significant for all results. Findings: The average subcutaneous tissue thickness in the injection area was determined as 15.44±8.01 mm and the average tissue thickness there was determined as 31.75±11.86 mm. The subcutaneous tissue thickness in women was found more than the subcutaneous tissue thickness in men. When the tissue thicknesses 2 and 4 cm around the injection area were analyzed, it was found that the area where the total tissue thickness was the least was over 2 cm (41.67±14.83) and over 4 cm (35.79±15.55) of the injection area. It was determined that the average total thickness 4 cm around the injection area was less than 38 mm in underwight individuals. Conclusions: According to the results obtained from the study, the weight and body mass index of the individual should be considered in the choice of the injection area and the length of the needle to be used when the ventrogluteal injection area was used in intramuscular injections. Especially in obese individuals, longer needles can be preferred. Besides, it must be thought that there may be the risk of bone injury 4 cm around the injection area in asthenic individuals and individuals with normal weight. Moreover, since the individuals’ having a large waist and hip circumference is related to their subcutaneous tissue thickness, it is recommended that long needles should be chosen in these individuals.

Publisher

Uluslararasi Insan Bilimleri Dergisi

Subject

General Medicine

Reference22 articles.

1. Burbridge, B.E. (2007). Computed tomographic measurement of gluteal subcutane-ous fat thickness in reference to failure of gluteal intramuscular injections. Can. Assoc. Radiol. J., 58 (2), 72–75.

2. Cocoman, A. & Murray, J. (2006). IM injections: how's your technique. World Ir. Nurs, 14(4), 50–51.

3. Cook, I.F. (2015). Best vaccination practice and medically attended injection site events following deltoid intramuscular injection. Hum. Vaccin Immunother, 11 (5), 1184–1191. doi:10.1080/21645515.2015.1017694

4. Donaldson, C. & Green, J. (2005). Using the ventrologluteal site for intramuscular injection. Nurs. Times, 101 (16), 36–38.

5. Greenway, K. (2014). Rituals in nursing: intramuscular injections. J. Clin. Nurs, 23, 3583–3588. doi: 10.1111/jocn.12627

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3