Affiliation:
1. University Center of Americas, São Paulo, Brazil.
Abstract
Diabetes is a worldwide health problem, a metabolic disorder that can lead to serious complications and damage to all vital organs. The resulting complications can be prevented with regular monitoring and maintenance of blood glucose level. The present review study aims to gather information on current methods for monitoring capillary blood glucose. Scientific articles were consulted in national and international journals, in addition to the Guidelines of the Brazilian Society of Diabetes and 9th Edition of the Diabetes Atlas of the International Diabetes Federation, American Diabetes Association, Ministry of Health and Brazilian Institute of Geography and Statistics (IBGE) data. Non-invasive methods include impedance spectroscopy, optical coherence tomography, photoacoustic spectroscopy, mid and near infrared spectroscopy, photoplethysmography. The advantages, in general, of non-invasive methods, seek ease of implementation and use, cost, accuracy in blood glucose measurement. The main disadvantages are physical parameters that can interfere with glucose measurement, as well as environmental variations. Interferences due to physiological factors can be eliminated using filtering processes, which suppress noise and increase effective information. With the present study, it is possible to conclude that there is a need to develop a non-invasive, painless, easily accessible method, without tissue damage, providing cost savings for the health system, considering quality of life, functional limitations, social and financial stress, emotional discomfort and depression in individuals with diabetes mellitus.
Reference13 articles.
1. ABBOTT BRASIL, FreeStyle® Libre, novo monitor de glicose da Abbott. São Paulo, 2015. Disponível em: https://www.abbottbrasil.com.br/imprensa/noticias/press-releases/freestyle-- libre--novo-monitor-de-glicose-que-elimina-a-necessid.html. Acesso em 25 out 2020.
2. BRINCE, P. et al. Design and Development of Non invasive Glucose Measurement System MEMS and Sensors Division. School of Electronics Engineering, VIT University, Vellore, India. IEEE. 2012.
3. FERRAZ, Denis P.; MAIA, Frederico F. R.; ARAUJO, Levimar R.. Glicemia capilar em ponta do dedo versus lóbulo de orelha: estudo comparativo dos valores resultantes e preferência dos pacientes. Arq Bras Endocrinol Metab. São Paulo, vol. 48, n.3, p. 389-393, June, 2004.
4. GALINDO, Rodolfo J. et al. Comparison of the FreeStyle Libre Pro flash continuous glucose monitoring (CGM) system and point-of-care capillary glucose testing in hospitalized patients with type 2 diabetes treated with basal-bolus insulin regimen. Diabetes Care, v. 43, n. 11, p. 2730-2735, 2020. Disponível em: < https://care.diabetesjournals.org/content/43/11/2730.full>. Acesso em: 30 out 2020.
5. GROSS, Jorge L. et al . Diabetes Melito: Diagnóstico, Classificação e Avaliação do Controle Glicêmico. Arq Bras Endocrinol Metab, São Paulo, v. 46, n. 1, p. 16-26, Feb. 2002.