Validation and Usability Evaluation of Mobile Application to Monitor Real-Time Exercise Heart Rate Zone
-
Published:2022-03-18
Issue:2
Volume:30
Page:1567-1581
-
ISSN:2231-8526
-
Container-title:Pertanika Journal of Science and Technology
-
language:en
-
Short-container-title:JST
Author:
Asraff Muhammad Iskandar,Linoby Adam,Rodzi Muhammad Azamuddin,Abdul Jamil Muhammad Mahadi,Latif Rozita Abdul,Norhamazi Iqbal
Abstract
A mobile application to monitor heart rate (HR) during an exercise called Chromozone was developed to enable a user to regulate exercise intensity using a color-coded system rather than numerical display in the most conventional device. In this study, the agreement of HR from Chromozone was compared against the HR dataset from a clinically accepted electrocardiogram (ECG) on different exercise intensity and to assess its reliability by intra-day repeated assessments. Additionally, the usability aspect of the Chromozone smartphone application was also assessed. Forty-two participants underwent self-selected exercise intensities (based on individual HR reserve) included for 5-min followed by a cool-down period (3-min). A 20-min rest period was given to the participant before repeating the same exercise protocol two more times. Chromozone was found to generate excellent criterion-concurrent validity (r = 0.998, p < 0.001) and acceptable bias of 1.96 bpm (Limits of Agreement; LoA: 3.07 to -3.51) for relative and absolute agreement, respectively. Similarly, relative (intraclass correlation coefficient test: 0.998, p < 0.001) and absolute (within-subject coefficient of variation: 1.95 ± 1.4%) reliability using Chromozone application shows an excellent consistency. Additionally, this study also showed that the usability level of the Chromozone application is beyond the satisfactory level. The outcome of this work provides strong support for Chromozone application as a valid and reliable exercise HR monitoring tool that could potentially help athletes, active individuals as well as the clinical population to monitor and regulate their exercise training regime more effectively.
Publisher
Universiti Putra Malaysia
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference25 articles.
1. Andrade, A., Casagrande, P., Bevilacqua, G., Pereira, F., Matte, D., & Coimbra, D. (2019). Burnout in elite junior tennis players: A multiple case study. Revista de Psicologia Del Deporte, 28(4), 97-105. 2. Bland, J., & Altman, D. (1987). Caveat doctor: A grim tale of medical statistics textbooks. British Medical Journal (Clinical Research Ed.), 295(6604), 979. https://doi.org/10.1136/bmj.295.6604.979 3. Bull, F., Al-Ansari, S., Biddle, S., Borodulin, K., Buman, M., Cardon, G., Carty, C., Chaput, J., Chastin, S., Chou, R., Dempsey, P., Dipietro, L., Ekelund, U., Firth, J., Friedenreich, C., Garcia, L., Gichu, M., Jago, R., Katzmarzyk, P., … & Willumsen, J. (2020). World Health Organization 2020 guidelines on physical activity and sedentary behaviour. British Journal of Sports Medicine, 54(24), 1451-1462. https://doi.org/10.1136/bjsports-2020-102955 4. Coppetti, T., Brauchlin, A., Müggler, S., Attinger, A., Templin, C., Schönrath, F., Hellermann, J., Lüscher, T., Biaggi, P., & Wyss, C. (2017). Accuracy of smartphone apps for heart rate measurement. European Journal of Preventive Cardiology, 24(12), 1287-1293. https://doi.org/10.1177/2047487317702044 5. Gaynor, M., Sawyer, A., Jenkins, S., & Wood, J. (2019). Variable agreement between wearable heart rate monitors during exercise in cystic fibrosis. ERJ Open Research, 5(4), 00006-02019. https://doi.org/10.1183/23120541.00006-2019
|
|