Author:
Mohd Shukor Fatin Azirah,Zainuddin Hedzlin,Jamian Jasrul Jamani,Muhammad Nurmalessa,Muhammad Khir Farah Liyana,Abdul Rahman Noor Hasliza
Abstract
The performance status of a grid-connected photovoltaic (GCPV) system is denoted by performance indices, namely performance ratio, capacity factor, and even through power acceptance ratio (AR), as documented in Malaysia Standard (MS) procedures for acceptance test of GCPV testing and commissioning (TNC). Even though AR analysis can be either on the DC or AC side, the MS TNC procedures implemented analysis on the AC side. Therefore, the question arises whether there is any significant difference when using AC AR analysis compared to DC AR analysis in evaluating the system performance. Thus, this paper evaluates the differences between applying DC AR analysis and AC AR analysis in accessing the performance of the ten kWp GCPV system in Malaysia. The AR analytical analysis employed the 2019 one-year historical data of solar irradiance, module temperature, DC power, and AC power. The results demonstrated that the monthly AC AR were consistently lower than DC AR with a percentage difference of approximately 3%. The percentage discrepancy was due to the variation of actual inverter efficiencies compared to the declared constant value by the manufacturer used in the AR prediction model. These findings have verified a significant difference between DC AR analysis and AC AR analysis. Most importantly, this study has highlighted the significance of AC AR analysis compared to DC AR analysis as a tool to evaluate GCPV system performance because AC AR has taken an additional factor into consideration, which is the inverter efficiency variation.
Publisher
Universiti Putra Malaysia
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference18 articles.
1. Appiah, A. Y., Zhang, X., Ayawli, B. B. K., & Kyeremeh, F. (2019). Review and performance evaluation of photovoltaic array fault detection and diagnosis techniques. International Journal of Photoenergy, 2019, Article 6953530. https://doi.org/10.1155/2019/6953530
2. Hansen, C., Stein, J., & Riley, D. (2012). Effect of time scale on analysis of PV system performance. Sandia National Laboratories. https://doi.org/10.13140/2.1.1150.3368
3. Humada, A. M., Hojabri, M., Mohamed, M. B., Sulaiman, M. H., & Dakheel, T. H. (2014). A proposed method of photovoltaic solar array configuration under different partial shadow conditions. In Advanced Materials Research (Vol. 983, pp. 307-311). Trans Tech Publications LTD. https://doi.org/10.4028/www.scientific.net/AMR.983.307
4. Hussin, M. Z., Omar, A. M., Zain, Z. M., & Shaari, S. (2013). Performance of grid-connected photovoltaic system in equatorial rainforest fully humid climate of Malaysia. International Journal of Applied Power Engineering (IJAPE), 2(3), 105-114. https://doi.org/10.11591/ijape.v2i3.2090
5. IEC TS 61724. (2016). Photovoltaic system performance - Part 3: Energy evaluation method. International Electrotechnical Commission.