THE PERMEABILITY OF GLOMERULAR CAPILLARIES TO GRADED DEXTRANS

Author:

Caulfield John P.1,Farquhar Marilyn G.1

Affiliation:

1. From the Section of Cell Biology, Yale University School of Medicine, New Haven, Connecticut 06510

Abstract

Graded dextrans have been used as tracers to identify the primary permeability barrier(s) to macromolecules among the structural elements (endothelium, mesangium, basement membrane, epithelium) of the glomerular capillary wall. Three narrow-range fractions of specified molecular weights and Einstein-Stokes radii (ESR) were prepared by gel filtration: (a) 32,000 mol wt, ESR = 38 Å; (b) 62,000 mol wt, ESR = 55 Å; and (c) 125,000 mol wt, ESR = 78 Å. These fractions are known to be extensively filtered, filtered in only small amounts, and largely retained, respectively, by the glomerular capillaries. Tracer solutions were infused i.v. into Wistar-Furth rats, and the left kidney was fixed after 5 min to 4 h. The preparations behaved as predicted: initially, all three fractions appeared in the urinary spaces, with 32,000 > 62,000 » 125,000. The smallest fraction was totally cleared from the blood and urinary spaces by 2.5 h, whereas the intermediate and largest fractions were retained in the circulation at high concentrations up to 4 h. With all fractions, when particles occurred in high concentration in the capillary lumina, they were present in similarly high concentrations in the endothelial fenestrae and inner (subendothelial) portions of the basement membrane, but there was a sharp drop in their concentration at this level—i.e., between the inner, looser portions of the basement membrane and its outer, more compact portions. With the two largest fractions, accumulation of particles occurred against the basement membrane in the mesangial regions with time. No accumulation was seen with any of the fractions in the epithelial slits or against the slit membranes. Dextran was also seen in phagosomes in mesangial cells, and in absorption droplets in the glomerular and proximal tubule epithelium. It is concluded that the basement membrane is the main glomerular permeability barrier to dextrans, and (since their behavior is known to be similar) to proteins of comparable dimensions (40,000–200,000 mol wt). The findings are discussed in relation to previous work using electron-opaque tracers to localize the glomerular permeability barrier and in relation to models proposed for the functions of the various glomerular structural elements.

Publisher

Rockefeller University Press

Subject

Cell Biology

Cited by 268 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3