Abstract
Objective: We aimed to evaluate the accuracy of the classification of carotid plaque vulnerability (unstable vs. stable plaques) by neurosurgical residents based on carotid ultrasonography (US) images.Methods: A total of 405 subjects with 995 images were included in the study. Using a neuroradiologist’s decision as the reference value, the classification results of five reviewers were analyzed. The sensitivity, specificity, and overall accuracy were estimated. Then, a pairwise comparison of the receiver operating characteristic (ROC) curve and precision-recall curve was performed to compare the reviewers’ classification accuracy.Results: The mean age of the subjects was 70.5 years (range, 44–91 years) and 223 (55.1%) were female. The number of unstable and stable plaques was 236 (24.7%) and 749 (75.3%), respectively. The best-balanced classification performance of plaque vulnerability was a sensitivity of 83.7% (95% confidence interval [CI], 78.5%–88.1%), specificity of 69.0% (95% CI, 65.6%–72.3%), and overall accuracy of 72.7% (95% CI, 69.8%–75.4%). The best ROC performance was an area under the curve (AUC) of 0.583 (95% CI, 0.552–0.614). The precision-recall curve also showed low classification accuracy among the reviewers (AUC difference: 0.028; 95% bootstrap CI, 0.007–0.048).Conclusion: The classification accuracy of neurosurgical residents to discriminate plaque vulnerability seen on carotid US images was low in a real-world clinical setting. Thus, it is necessary to develop systems that help to educate and automatically interpret plaque stability.
Funder
Korea Institute for Advancement of Technology
Ministry of Trade, Industry and Energy
Publisher
The Korean Society of Geriatric Neurosurgery