False-positive fourth-generation HIV test associated with autoimmune hemolytic anemia. Case report

Author:

Sánchez-Pardo SantiagoORCID,Osorio-Ramírez Jaime AndrésORCID,Choi-Park IsabelaORCID,Rojas-Holguín Daniel FelipeORCID,Bolívar-Mejía AdriánORCID

Abstract

Introduction: The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies. Estimates are that only 0.5% yield false positive results.Case description: 61-year-old female patient with a clinical picture consisting of malaise, unquantified fever, asthenia and adynamia. Laboratory tests revealed anemia, so a Coombs test was performed, obtaining a positive result along with other findings of mixed autoimmune hemolytic anemia. Two fourth-generation ELISA HIV screening tests were performed obtaining positive results. Given the national recommendations on the diagnosis of HIV infection, a viral load was performed, which turned out to be negative, so the result was considered a false positive.Discussion: Clinical and biological factors are related to false positive results. There are descriptions about autoimmunity phenomena, such as systemic lupus erythematosus or autoimmune hemolytic anemia, with few cases in older adults.Conclusions: Rapid tests have changed the diagnosis of HIV infection worldwide; however, like any other diagnostic test, they may yield false positive results with differential diagnoses, including autoimmune hemolytic anemia.

Publisher

Universidad Nacional de Colombia

Subject

General Medicine,General Chemistry

Reference19 articles.

1. Teva I, Bermúdez MP, Ramiro MT, Buela-Casal G. Situación epidemiológica actual del VIH/SIDA en Latinoamérica en la primera década del siglo XXI: Análisis de las diferencias entre países. Rev. méd. Chile. 2012;140(1):50-8. http://doi.org/c5rk.

2. Mejía-Arreguí MH. Anemias hemolíticas autoinmunes. Rev MédInst Mex Seguro Soc.2005;43(Suppl 1):S25-8.

3. Alfonso-Valdés ME, Bencomo-Hernández A, Espinosa-Martínez E, Guerrero-Calderón R, Guerra-Borrego E, Guerrero-Calderón AI. Caracterización de pacientes adultos con anemia hemolítica autoinmune atendidos en el Instituto de Hematología e Inmunología. Rev Cubana Hematol Inmunol Hemoter. 2009 [cited2018Oct13];25(3). Available from: https://bit.ly/31ncpTA.

4. Liu P, Jackson P, Shaw N, Heysell S. Spectrum of false positivity for the fourth-generation human immunodeficiency virus diagnostic tests. AIDS Res Ther. 2016;13:1. http://doi.org/c65h.

5. Shida S, Takahashi N, Fujishima N, Kameoka Y, Nara M, Fujishima M, et al. False-positive human immunodeficiency virus antibody test and autoimmune hemolytic anemia in a patient with angioimmunoblastic T-cell lymphoma. Intern Med. 2011;50(20):2383-7. http://doi.org/dhgps8.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3