Abstract
Introduction: The fourth-generation ELISA human immunodeficiency virus (HIV) screening test has a high sensitivity and specificity >99% to detect both antigens and antibodies. Estimates are that only 0.5% yield false positive results.Case description: 61-year-old female patient with a clinical picture consisting of malaise, unquantified fever, asthenia and adynamia. Laboratory tests revealed anemia, so a Coombs test was performed, obtaining a positive result along with other findings of mixed autoimmune hemolytic anemia. Two fourth-generation ELISA HIV screening tests were performed obtaining positive results. Given the national recommendations on the diagnosis of HIV infection, a viral load was performed, which turned out to be negative, so the result was considered a false positive.Discussion: Clinical and biological factors are related to false positive results. There are descriptions about autoimmunity phenomena, such as systemic lupus erythematosus or autoimmune hemolytic anemia, with few cases in older adults.Conclusions: Rapid tests have changed the diagnosis of HIV infection worldwide; however, like any other diagnostic test, they may yield false positive results with differential diagnoses, including autoimmune hemolytic anemia.
Publisher
Universidad Nacional de Colombia
Subject
General Medicine,General Chemistry
Reference19 articles.
1. Teva I, Bermúdez MP, Ramiro MT, Buela-Casal G. Situación epidemiológica actual del VIH/SIDA en Latinoamérica en la primera década del siglo XXI: Análisis de las diferencias entre países. Rev. méd. Chile. 2012;140(1):50-8. http://doi.org/c5rk.
2. Mejía-Arreguí MH. Anemias hemolíticas autoinmunes. Rev MédInst Mex Seguro Soc.2005;43(Suppl 1):S25-8.
3. Alfonso-Valdés ME, Bencomo-Hernández A, Espinosa-Martínez E, Guerrero-Calderón R, Guerra-Borrego E, Guerrero-Calderón AI. Caracterización de pacientes adultos con anemia hemolítica autoinmune atendidos en el Instituto de Hematología e Inmunología. Rev Cubana Hematol Inmunol Hemoter. 2009 [cited2018Oct13];25(3). Available from: https://bit.ly/31ncpTA.
4. Liu P, Jackson P, Shaw N, Heysell S. Spectrum of false positivity for the fourth-generation human immunodeficiency virus diagnostic tests. AIDS Res Ther. 2016;13:1. http://doi.org/c65h.
5. Shida S, Takahashi N, Fujishima N, Kameoka Y, Nara M, Fujishima M, et al. False-positive human immunodeficiency virus antibody test and autoimmune hemolytic anemia in a patient with angioimmunoblastic T-cell lymphoma. Intern Med. 2011;50(20):2383-7. http://doi.org/dhgps8.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献