The evaluation of point-of-care testing for determining hemoglobin levels in geriatric intensive care patients

Author:

Honca Tevfik1,Honca Mehtap2

Affiliation:

1. Department of Health, Republic of Turkey Ministry of National Defense, Ankara, Turkey

2. Department of Anesthesiology and Reanimation, Kecioren Training and Research Hospital, Ankara, Turkey, Phone: +90 312 3569000, Fax: +90 312 3569002

Abstract

AbstractBackgroundThe aim of the present study was to compare hemoglobin (Hb) levels determined by point-of-care testing (POCT) HemoCue® and arterial blood gas analyzer using an automated hematology analyzer in critically ill geriatric patients.MethodsForty geriatric patients requiring intensive care treatment were included in the study. Arterial blood sample was analyzed using HemoCue® (HemoCue®; Hb 201+, Angelholm, Sweden) (HbHemoCueArterial), blood gas analyzer (Techno Medica, Gastat1800 series, Japan) (HbBGA) and an automated hematology analyzer (Cell Dyne 3700 System, Abbott Laboratories, USA) (HbLab) as a reference method. Capillary blood measurements were performed (HbHemoCueCapillary) using HemoCue® at bedside. Bland-Altman analysis was applied to the results.ResultsWe found a positive correlation between the Hb measurements of HemoCueCapillary, HemoCueArterial and automated hematology analyzer (r-values were 0.799 and 0.922, respectively) and p<0.001. There was also a positive correlation between the Hb measurements of blood gas analyzer and automated hematology analyzer (r = 0.878) and p<0.001. The bias and limits of agreement were 0.32 and −2.5±3.14 g/dL for the HbHemoCueCapillary, 0.64 and −1.03±2.31 g/dL for the HbHemoCueArterial and −1.2 and −4.45±2.05 g/dL for the HbBGA. Inotropic agent administration did not affect the Hb values in all groups.ConclusionsBoth HemoCueCapillary and HemoCueArterial are sufficiently accurate and correlated with automated hematology analyzer in geriatric critically ill patients if used correctly. In terms of Hb levels, arterial and capillary blood sample measurements with HemoCue® provided more clinically acceptable accuracy than blood gas analysis system.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Medical Laboratory Technology,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3