Corrosion of copper intrauterine devices: review and recent developments

Author:

Bastidas David M.1ORCID,Valdez Benjamin2ORCID,Schorr Michael2ORCID,Bastidas Jose M.3ORCID

Affiliation:

1. National Center for Education and Research on Corrosion and Materials Performance (NCERCAMP-UA), Department of Chemical, Biomolecular, and Corrosion Engineering , The University of Akron , 302 E Buchtel Ave , Akron, OH 44325-3906 , USA

2. Laboratory of Materials, Minerals and Corrosion, Institute of Engineering , Autonomous University of Baja California (UABC) , Blvd. Benito Juarez and Normal St. , 21280 Mexicali , Mexico

3. National Center for Metallurgical Research (CENIM), CSIC , Ave. Gregorio del Amo 8 , 28040 Madrid , Spain

Abstract

Abstract A systematic review of the literature about the corrosion of copper in intrauterine devices (IUDs) was conducted, an important topic of copper application that apparently may not be well known to a broad corrosion audience. Copper IUDs (Cu-IUDs) are one of the most widely used contraceptive methods around the world, particularly in China, India, and Latin America. The contraceptive method is based on the release of copper ions from a Cu-IUD. Copper ions enhance the inflammatory response in the uterine cavity and reach concentrations in the luminal fluids of the genital tract, which are toxic for spermatozoa and embryos. A description is made of the different types of Cu-IUD used, the traditional T-shaped device, copper nanoparticles inside a polymeric matrix, and other shapes. This review aims to discuss the main parameters affecting the efficiency of a Cu-IUD, the contraceptive mechanism, and the shape of the device. The high copper corrosion rate immediately after insertion in the uterus (“burst release”) is discussed, which presents values of the order of up to 296 μg/day, causing side effects such as bleeding and pain, with an exponential decay defining a steady-state plateau after 1–2 months of insertion with values of 40 μg/day for a 200 mm2 Cu-IUD. This plateau is maintained over the life span of a Cu-IUD, in which the copper dissolution rate is as low as 2 μg/day for a Cu-IUD with indomethacin keeping up the contraceptive action mechanism, the concentration of copper that needs to be higher than 10−6 mol/l.

Publisher

Walter de Gruyter GmbH

Subject

General Materials Science,General Chemical Engineering,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3