Mass spectrometric quantification of urinary 6-sulfatoxymelatonin: age-dependent excretion and biological variation

Author:

van Faassen Martijn1,van der Veen Anna1,van Ockenburg Sonja2,de Jong Helma1,de Vries Elisabeth G. E.3,Kema Ido P.1

Affiliation:

1. Department of Laboratory Medicine , University of Groningen, University Medical Center Groningen , Groningen , The Netherlands

2. Department of Endocrinology , University of Groningen, University Medical Center Groningen , Groningen , The Netherlands

3. Department of Medical Oncology , University Medical Center Groningen, University of Groningen , Groningen , The Netherlands

Abstract

Abstract Objectives Regulators of circadian rhythm, including melatonin, influence fundamental biological processes. Measuring the melatonin metabolite 6-sulfatoxymelatonin in urine can estimate melatonin production. 6-sulfatoxymelatonin is mainly analyzed by immunoassays, but these methods are hampered by cross-reactivity and poor reproducibility when used to analyze small molecules. Therefore, we validated a high-throughput liquid chromatography with tandem mass spectrometry (LC–MS/MS) method to quantify 6-sulfatoxymelatonin in urine. We evaluated age-dependent 24-h excretion of 6-sulfatoxymelatonin into urine and the biological variation of urinary excretion in healthy individuals. Methods The online solid phase extraction method combined with LC–MS/MS was validated according to international guidelines, and used to measure the excretion of 6-sulfatoxymelatonin into urine of 240 healthy individuals. Biological variation of 6-sulfatoxymelatonin excretion was examined in 10 healthy individuals. Results Urinary 6-sulfatoxymelatonin results were well within the validation criteria (interassay coefficient of variation: <5.4%, quantification limit: 0.2 nmol/L). There was an age-related decrease in 6-sulfatoxymelatonin excretion into 24-h urine [F(5, 234)=13.9; p<0.001]. Within-subject variation of 6-sulfatoxymelatonin was 39.2% in day urine, 15.1% in night urine, and 12.2% in 24-h urine. Between-subject variation was 39.1% in day urine, 37.9% in night urine, and 36.8% in 24-h urine. Conclusions This MS-based method enables straightforward, reproducible, and sensitive quantification of 6-sulfatoxymelatonin in urine. Urinary 6-sulfatoxymelatonin levels decreased with age. Biological variation of 6-sulfatoxymelatonin excretion into urine was high between subjects and lower within subjects, indicating that repeated measurements of 6-sulfatoxymelatonin in 24-h urine are needed in future studies.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine