Effect of collection matrix, platelet depletion, and storage conditions on plasma extracellular vesicles and extracellular vesicle-associated miRNAs measurements
Author:
Faraldi Martina1ORCID, Gomarasca Marta1ORCID, Perego Silvia1ORCID, Sansoni Veronica1ORCID, Banfi Giuseppe12ORCID, Lombardi Giovanni13ORCID
Affiliation:
1. Laboratory of Experimental Biochemistry & Molecular Biology , IRCCS Istituto Ortopedico Galeazzi , Milan , Italy 2. Vita-Salute San Raffaele University , Milan , Italy 3. Department of Athletics, Strength and Conditioning , Poznań University of Physical Education , Poznań , Poland
Abstract
Abstract
Objectives
The interest around circulating extracellular vesicles and their cargo in diagnostics has greatly increased; however, several pre-analytical variables affect their determination. In this study, we investigated the effects of sample matrix, processing, and plasma storage delay and temperature on extracellular vesicles and their miRNA content.
Methods
Blood was collected from 10 male volunteers in dipotassium ethylendiaminotetraacetate-coated tubes (K2EDTA), either with plasma-preparation tube (PPT) or without (K2E) gel separator. A stepwise centrifugation was applied to K2E aliquots to obtain platelet-poor plasma (PPP). K2E, PPP and PPT plasma, stored under different conditions, were assayed for extracellular vesicles concentration and size distribution, through dynamic laser light scattering, and microRNAs content, by qPCR.
Results
PPP samples were characterized by the lowest extracellular vesicles count and miRNA detectability. Although having no effects on extracellular vesicles total concentration, storage conditions influenced microRNAs detectability, mainly in PPP and PPT samples. Extracellular vesicles-associated miRNAs levels in K2E were, in general, higher than in PPP and to a very limited extent to PPT. Storage temperature and delay did not affect their profile in K2E samples.
Conclusions
Extracellular vesicles count and extracellular vesicles miRNA profile changed under the analyzed pre-analytical variables, showing the greatest stability in K2E samples. Since pre-analytical variables differently affected extracellular vesicles and their miRNA content, they should be considered in each experimental setting and clinical routine.
Funder
Italian Ministry of Health
Publisher
Walter de Gruyter GmbH
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference40 articles.
1. Bonini, P, Plebani, M, Ceriotti, F, Rubboli, F. Errors in laboratory medicine. Clin Chem 2002;48:691–8. https://doi.org/10.1093/clinchem/48.5.691. 2. Lippi, G, Chance, JJ, Church, S, Dazzi, P, Fontana, R, Giavarina, D, et al.. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med 2011;49:1113–26. https://doi.org/10.1515/cclm.2011.600. 3. Dugue, B, Lombardi, G, Banfi, G. What everybody should know about postural changes. Scand J Clin Lab Invest 2018;78:407–10. https://doi.org/10.1080/00365513.2018.1473634. 4. Lombardi, G, Barbaro, M, Locatelli, M, Banfi, G. Novel bone metabolism-associated hormones: the importance of the pre-analytical phase for understanding their physiological roles. Endocrine 2017;56:460–84. https://doi.org/10.1007/s12020-017-1239-z. 5. Cheng, HH, Yi, HS, Kim, Y, Kroh, EM, Chien, JW, Eaton, KD, et al.. Plasma processing conditions substantially influence circulating microRNA biomarker levels. PloS One 2013;8:e64795. https://doi.org/10.1371/journal.pone.0064795.
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|