New insights into SARS-CoV-2 Lumipulse G salivary antigen testing: accuracy, safety and short TAT enhance surveillance

Author:

Aita Ada1,Navaglia Filippo2,Moz Stefania2,Contran Nicole2,Barbaro Francesco3,Cattelan Anna Maria3,Padoan Andrea12ORCID,Cosma Chiara2,Faggian Diego2,Plebani Mario1ORCID,Basso Daniela12ORCID

Affiliation:

1. Department of Medicine – DIMED , University of Padova , Padova , Italy

2. Laboratory Medicine Unit , University Hospital of Padova , Padova , Italy

3. Tropical and Infectious Diseases Unit, University Hospital of Padova , Padova , Italy

Abstract

Abstract Objectives The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. Methods In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. Results Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943–0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. Conclusions CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3