Umbilical cord blood gases: probability of arterial or venous source in acidemia

Author:

Monneret Denis1,Stavis Robert L.2ORCID

Affiliation:

1. Service de Biochimie et Biologie Moléculaire, Laboratoire de Biologie Médicale Multi-Sites (LBMMS), Hospices Civils de Lyon (HCL) , Lyon , France

2. Grand Rounds Software, LLC , Bryn Mawr , PA , USA

Abstract

Abstract Objectives Umbilical cord blood gases (UBG) may be a critical element in the assessment of a depressed newborn infant but in some cases the arterial or venous UBG source is uncertain making clinical and/or medical-legal interpretation difficult. Objective: to estimate the probability of an arterial (ProbAS) or venous (ProbVS) UBG source depending on blood gas parameters in acidemic cases. Methods A total of 56,703 pairs of concomitant arterial and venous (CAV) UBG results assayed over an 8.8-year period were analyzed. Specimen pairs with preanalytical issues, duplicate source, or physiologically out-of-range or uninterpretable results were excluded. The 3,579 CAV-UBGs with an arterial and venous pH 6.70 to 7.25 were analyzed. Generalized additive model (gam)-based binomial logistic regressions were used to determine the ProbAS and ProbVS according to the blood gas parameters. Results The relative differences between arterial and venous medians were: pO2 ‒47%, pCO2 22%, pH −11%, and BD 4%. Below a median of 2.4 kPa, the lower the pO2, the higher the ProbAS. Above this value, the higher the pO2, the lower the ProbAS. An Excel worksheet is provided to calculate ProbAS and ProbVS from the regression model for different combinations of pH, pCO2, and pO2 values. Considering ProbAS and ProbVS above a cutoff 0.8, the model correctly identified the source in 56% of cases while 41% were indeterminant and 3% were erroneous. Conclusions The probability of an arterial or venous source of an umbilical blood gas can be estimated based on the pH, pCO2, and pO2 in most acidemic specimens.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3