External quality assessment of M-protein diagnostics: a realistic impression of the accuracy and precision of M-protein quantification

Author:

de Kat Angelino Corrie M.1,Jacobs Joannes F.M.1

Affiliation:

1. Department of Laboratory Medicine, Laboratory Medical Immunology , Radboud University Medical Center , Nijmegen , The Netherlands

Abstract

Abstract Objectives Studies that investigate the accuracy and precision of M-protein quantification are scarce. These studies are prone to give a biased view, since they are exclusively performed by institutions with international top-expertise on M-protein diagnostics. To obtain a realistic impression of the accuracy and precision of M-protein quantification, we studied results of 73 laboratories participating in the Dutch External Quality Assessment (EQA) program for M-protein diagnostics. Methods To measure accuracy, healthy serum was spiked with respectively 1 and 5 g/L human IgG-kappa monoclonal antibody daratumumab. To measure precision, five sera were selected to be repeatedly send to all blinded EQA-participants. Results The reported concentrations for the EQA-sample spiked with 5 g/L daratumumab ranged from 2.6 to 8.0 g/L (mean 4.9 g/L, between-laboratory CV = 23%). 98% of the participants detected and correctly characterized the 1 g/L daratumumab band. Both the accuracy (mean 1.7 g/L) and precision (between-laboratory CV = 46%) of this 1 g/L M-protein was poor. In the five EQA-samples that were repeatedly send to the same 73 participating laboratories, between-laboratory precision (mean CV = 25%) was significantly different than the within-laboratory precision (mean CV = 12%). Relatively poor precision was observed in sera with small M-proteins. Conclusions The EQA-data reveal a large variation in reported M-protein concentrations between different laboratories. In contrast, a satisfactory within-laboratory precision was observed when the same sample was repeatedly analyzed. The M-protein concentration is correlated with both accuracy and precision. These data indicate that M-protein quantification to monitor patients is appropriate, when subsequent testing is performed within the same laboratory.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司