Evaluation of carbohydrate-deficient transferrin measurements on the V8 capillary electrophoresis system and comparison with the IFCC approved HPLC reference method and N-Latex immunonephelometric assay

Author:

Jacobs Leo H.J.1,te Stroet Riekie M.1,Demir Ayse Y.1

Affiliation:

1. Department of Clinical Chemistry and Hematology , Meander Medical Centre , Amersfoort , The Netherlands

Abstract

Abstract Objectives Carbohydrate-deficient transferrin (CDT) measurements are commonly used for the identification and follow-up of individuals suspected of chronic alcohol abuse. This study describes the analytical characteristics of the CDT assay on the Helena Biosciences V8 electrophoresis analyzer and compares its diagnostic performance to the International Federation of Clinical Chemistry and Laboratory Medicine approved high performance liquid chromatography (HPLC) method and the N-Latex CDT immunonephelometric assay. Methods The analytical performance of the V8 assay, including the linearity and the imprecision, was studied at two separate locations. Method comparison analysis was performed by studying the correlation, bias and agreement between the V8, HPLC and the N-Latex assays in 231 patient samples. Results The total imprecision ranged between 5.1 and 24.3% and was ≤13.1% for samples with concentrations above the clinical cut-off value (≥1.62%). The method comparisons revealed excellent correlations with r2≥0.97 for all comparisons. Measurements on the V8 showed a bias of −0.83 (−22.24%) and −0.40 (−12.26%) with the HPLC and N-Latex assays, respectively. The assays showed excellent agreements (Kappa scores ≥ 0.8) in classifying subjects with elevated CDT values. Receiver operating characteristic (ROC)-curve analysis, using the HPLC classification as reference, revealed areas under the ROC-curves of 0.981 (95% CI, 0.97–0.99) and 0.996 (0.99–1.00) for the N-Latex and V8 assays, respectively. Conclusions CDT measurements on the V8 assay are highly correlated with both the HPLC and the N-Latex assay and show excellent agreement in classifying subjects with elevated CDT values. Overall, the V8 CDT analysis is a robust, reliable and effective method to measure CDT concentrations in serum samples.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3