Methodological considerations in determining sex steroids in children: comparison of conventional immunoassays with liquid chromatography-tandem mass spectrometry

Author:

Ankarberg-Lindgren Carina1ORCID,Becker Charlotte2,Svala Emilia3,Ryberg Henrik45

Affiliation:

1. Department of Pediatrics , Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg , Gothenburg , Sweden

2. Department of Clinical Chemistry and Pharmacology , University and Regional Laboratories Region Skåne , Malmö , Sweden

3. Equalis AB , Uppsala , Sweden

4. Department of Clinical Chemistry , Sahlgrenska University Hospital , Gothenburg , Sweden

5. Sahlgrenska Osteoporosis Centre, Centre for Bone and Arthritis Research, Department of Internal Medicine and Clinical Nutrition , Institute of Medicine, Sahlgrenska Academy, University of Gothenburg , Gothenburg , Sweden

Abstract

Abstract Objectives In laboratory medicine, external quality assessment (EQA) schemes have become versatile tools for detecting analytical flaws. However, EQA schemes are lacking for pediatric sex steroid levels. We aimed to investigate the suitability of different estradiol and testosterone immunoassays in a pediatric setting in comparison with clinical liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays. Methods The study was conducted by staff and the advisory group on endocrinology at Equalis, the Swedish provider of EQA schemes for laboratory medicine. The test material consisted of five pooled serum samples from children who were either prepubertal or in puberty. Clinical laboratories enrolled in Equalis EQA schemes for estradiol and testosterone were invited to participate, as were clinical laboratories using LC-MS/MS-assays. Samples were analyzed by either routine immunoassays (n=18) or in-house LC-MS/MS assays (n=3). Results For estradiol, LC-MS/MS assays showed a high degree of conformity with interlaboratory coefficients of variation (CV) below 24.2 %. Reported levels were between 4.9 ± 1.2 and 33.9 ± 1.6 pmol/L (group mean ± standard deviation). The direct immunoassays had lower precision; their CVs were up to 81.4 %. Reported concentrations were between 25.3 ± 18.1 and 45.7 ± 19.4 pmol/L, an overestimation compared to LC-MS/MS. Testosterone LC-MS/MS also showed a high degree of conformity, CVs were below 13.4 %, and reported concentrations were from 0.06 ± 0.00 to 1.00 ± 0.11 nmol/L. The direct immunoassays had a larger discrepancy between results; CVs were up to 95.8 %. Concentrations were between 0.12 ± 0.11 and 0.85 ± 0.23 nmol/L. Conclusions For the safe diagnosis and determination of sex steroids in children, analysis with mass spectrometry-based methods is recommended.

Funder

Region Skåne

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3