Comparison of the reliability of Gram-negative and Gram-positive flags of the Sysmex UF-5000 with manual Gram stain and urine culture results

Author:

Enko Dietmar12,Stelzer Ingeborg2,Böckl Michael2,Schnedl Wolfgang J.3,Meinitzer Andreas1,Herrmann Markus1,Tötsch Martin4,Gehrer Michael4

Affiliation:

1. Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz , Graz , Austria

2. Institute of Clinical Chemistry and Laboratory Medicine, General Hospital Hochsteiermark , Leoben , Austria

3. Practice for General Internal Medicince , Bruck/Mur , Austria

4. Institute of Pathology, General Hospital Hochsteiermark , Leoben , Austria

Abstract

Abstract Objectives Recently, the fully automated flow cytometry-based UF-5000 (Sysmex Corboration, Kobe, Japan) urine sediment analyzer was developed providing bacteria (BACT) info flags for more accurate bacterial discrimination of urinary tract infections (UTIs). This study aimed to compare the reliability of the UF-5000 BACT-info flags with manual Gram stain and urine culture as the gold standard method. Methods A total of 344 urine samples were analyzed on the UF-5000 and compared with manual microscopic Gram stain and urine cultures. Agreement was assessed by Cohen’s kappa (κ) analysis. The Youden index was used to determine the optimal BACT and white blood cell (WBC) cut-off points for discriminating positive and negative urine cultures. Results Overall 98/344 (28.5%) samples were urine culture positive at a cut-off of ≥105 CFU/mL. “Gram-negative?” UF-5000 BACT-Info flags showed a better concordance of 25/40 (62.5%) with urine culture compared to Gram stain with 30/50 (60%). The results for UF-5000 discrimination of Gram-positive and Gram-negative microorganisms demonstrated a substantial (κ = 0.78) and fair (κ = 0.40) agreement with urine culture. Optimal cut-off points detecting positive urine cultures were 135 BACT/µL (sensitivity [SE]: 92.1%, specificity [SP]: 85.4%, positive predictive value [PPV]: 71%, negative predictive value [NPV]: 96%) and 23 WBC/µL (SE: 73.5%, SP: 84.1%, PPV: 65%, NPV: 89%). Conclusions The UF-5000 analyzer (Sysmex) is a reliable diagnostic tool for UTI screening. The displayed BACT-Info flags allow a quick diagnostic orientation for the clinician. However, the authors suggest verifying the automated Gram categories with urine culture.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3