Detection of subarachnoid haemorrhage with spectrophotometry of cerebrospinal fluid – a comparison of two methods

Author:

Clarin Marcus1,Petersson Annika1,Zetterberg Henrik23456,Ekblom Kim78

Affiliation:

1. Clinical Chemistry and Transfusion Medicine , Växjö Central Hospital , Växjö , Sweden

2. Department of Psychiatry and Neurochemistry , Institute of Neuroscience and Physiology, Sahlgrenska Academy at the University of Gothenburg , Gothenburg , Sweden

3. Clinical Neurochemistry Laboratory , Sahlgrenska University Hospital , Mölndal , Sweden

4. Department of Neurodegenerative Disease , UCL Institute of Neurology , London , UK

5. UK Dementia Research Institute at UCL , London , UK

6. Hong Kong Center for Neurodegenerative Diseases , Hong Kong , China

7. Department of Research and Development , Region Kronoberg, Växjö , Sweden

8. Department of Medical Biosciences , Clinical Chemistry, Umeå University , Umeå , Sweden

Abstract

Abstract Objectives Spectrophotometric absorption curve analysis of cerebrospinal fluid (CSF) for oxyhaemoglobin and bilirubin is necessary to accurately diagnose subarachnoid haemorrhage (SAH) in patients with typical symptoms but with negative findings on X-ray examinations. In this study, we evaluated the performance of two methods for interpreting absorption curves; one method from the United Kingdom National External Quality Assessment Service (UK-NEQAS) and the other from the national quality assurance programme in Sweden (Equalis). Methods Consecutive absorbance curves (n=336) were interpreted with two different methods, and their performance was compared to the diagnosis as stated in the patient records. Results The UK-NEQAS method displayed equal sensitivity to the Equalis method, but the specificity of the UK-NEQAS method was significantly higher than the Equalis method resulting in fewer false positive results. For UK-NEQAS, a positive predictive value (PPV) of 84.6% and a negative predictive value (NPV) of 99.7% were observed, whereas the Equalis method had a PPV of 27.5% and an NPV of 99.7%. Conclusions The semi-automated method based on the guidelines from UK-NEQAS provides an efficient and correct interpretation of absorbance curves with short turn-around times. We propose using this method for the routine interpretation of CSF spectrophotometric curves.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3