Establishing metrological traceability for small molecule measurands in laboratory medicine

Author:

Seger Christoph12,Kessler Anja3,Taibon Judith4

Affiliation:

1. Labordiagnostic St. Gallen West AG , St. Gallen , Switzerland

2. Institute of Pharmacy, CCB – Centrum of Chemistry and Biomedicine, CMBI – Center for Molecular Biosciences, University of Innsbruck , Innsbruck , Austria

3. Stiftung für Pathobiochemie und Molekulare Diagnostik , Bonn , Germany

4. Roche Diagnostics GmbH , Penzberg , Germany

Abstract

Abstract For molecules that can be well described metrologically in the sense of the definition of measurands, and which can also be recorded analytically as individual substances, reference measurement service traceability to a metrologically sound foundation is a necessity. The establishment of traceability chains must be initiated by National Metrology Institutes (NMIs) according to applicable standards; they are at the top and leading position in this concept. If NMIs are not in the position to take up this task, alternative approaches must be sought. Traceability initiatives established by in vitro device industry or academia must meet the quality standards of NMIs. Adherence to International Organization for Standardization (ISO) procedure 15193 must be a matter of course for the establishment of reference measurement procedures (RMPs). Certified reference material (CRM) characterization must be thorough, e.g., by the application of quantitative nuclear magnetic resonance measurements and by adherence to ISO 15194. Both for RMPs and CRMs Joint Committee for Traceability in Laboratory Medicine (JCTLM) listing must be the ultimate goal. Results must be shared in a transparent manner to allow other stakeholders including NMIs to reproduce and disseminate the reference measurement procedures.

Funder

Ashfield MedComms was funded by Roche Diagnostics GmbH

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference105 articles.

1. ILAC. ILAC policy on metrological traceability of measurement results 2020. Available from: https://ilac.org/publications-and-resources/ilac-policy-series/ [Accessed September 2022].

2. Joint Committee for Guides in Metrology. International vocabulary of metrology – basic and general concepts and associated terms (VIM), 3rd ed. JCGM 200; 2012. Available from: http://www.bipm.org/vim [Accessed August 2022].

3. Cali, JP. An idea whose time has come. Clin Chem 1973;19:291–3. https://doi.org/10.1093/clinchem/19.3.291.

4. Fasce, CFJr, Rej, R, Copeland, WH, Vanderlinde, RE. A discussion of enzyme reference materials: applications and specifications. Clin Chem 1973;19:5–9. https://doi.org/10.1093/clinchem/19.1.5.

5. Stepman, HC, Tiikkainen, U, Stöckl, D, Vesper, HW, Edwards, SH, Laitinen, H, et al.. Measurements for 8 common analytes in native sera identify inadequate standardization among 6 routine laboratory assays. Clin Chem 2014;60:855–63. https://doi.org/10.1373/clinchem.2013.220376.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3