The development of autoverification system of lymphocyte subset assays on the flow cytometry platform

Author:

Shi Jue12,Mu Run-Qing3,Wang Pan12,Geng Wen-Qing12,Jiang Yong-Jun12,Zhao Min3,Shang Hong123,Zhang Zi-Ning12

Affiliation:

1. NHC Key Laboratory of AIDS Immunology (China Medical University) , National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University , Shenyang , P.R. China

2. Key Laboratory of AIDS Immunology , Chinese Academy of Medical Sciences , Shenyang , P.R. China

3. Department of Laboratory Medicine, National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University , Shenyang , P.R. China

Abstract

Abstract Objectives Peripheral blood lymphocyte subsets are important parameters for monitoring immune status; however, lymphocyte subset detection is time-consuming and error-prone. This study aimed to explore a highly efficient and clinically useful autoverification system for lymphocyte subset assays performed on the flow cytometry platform. Methods A total of 94,402 lymphocyte subset test results were collected. To establish the limited-range rules, 80,427 results were first used (69,135 T lymphocyte subset tests and 11,292 NK, B, T lymphocyte tests), of which 15,000 T lymphocyte subset tests from human immunodeficiency virus (HIV) infected patients were used to set customized limited-range rules for HIV infected patients. Subsequently, 13,975 results were used for historical data validation and online test validation. Results Three key autoverification rules were established, including limited-range, delta-check, and logical rules. Guidelines for addressing the issues that trigger these rules were summarized. The historical data during the validation phase showed that the total autoverification passing rate of lymphocyte subset assays was 69.65% (6,941/9,966), with a 67.93% (5,268/7,755) passing rate for T lymphocyte subset tests and 75.67% (1,673/2,211) for NK, B, T lymphocyte tests. For online test validation, the total autoverification passing rate was 75.26% (3,017/4,009), with 73.23% (2,191/2,992) for the T lymphocyte subset test and 81.22% (826/1,017) for the NK, B, T lymphocyte test. The turnaround time (TAT) was reduced from 228 to 167 min using the autoverification system. Conclusions The autoverification system based on the laboratory information system for lymphocyte subset assays reduced TAT and the number of error reports and helped in the identification of abnormal cell populations that may offer clues for clinical interventions.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3