Evaluation of serum electrolytes measurement through the 6-year trueness verification program in China

Author:

Yan Ying1,Pu Yungang1,Zeng Jie1,Zhang Tianjiao1,Zhou Weiyan1,Zhang Jiangtao1,Wang Jing1,Zhang Chao1,Chen Wenxiang1,Zhang Chuanbao1

Affiliation:

1. National Center for Clinical Laboratories, Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, National , Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences , Beijing , P.R. China

Abstract

Abstract Objectives The National Center for Clinical Laboratories (NCCL) in China initiated a serum electrolyte trueness verification (ETV) program in 2014 for measurement standardization. Methods Every year, two levels of fresh frozen commutable serum samples determined by inductively coupled plasma mass spectrometry (ICP-MS) reference methods were transported to participating clinical laboratories for the measurement of sodium, potassium, calcium and magnesium. Both samples were measured 15 times in 3 days, and the mean values and coefficient variations (CVs) were calculated from the results. The tolerance limits of trueness (bias), precision (CV) and accuracy (TE) based on the biological variation database were used as the evaluation criteria. The overall trend of the ETV program over 6 years was surveyed by calculating the pass rates of the participating laboratories. The mean bias, inter-laboratory CV, and TE of all laboratory results were analysed. Furthermore, homogeneous and heterogeneous systems were compared, and the bias and CV results of mainstream analysis systems were analysed. Results Pass rates of the three quality specifications increased, and the overall mean bias and inter-laboratory CVs decreased. The homogeneous system was superior to the heterogeneous system for calcium and magnesium measurements. For sodium, potassium, calcium and magnesium, the minimum bias corresponded to Hitachi, Siemens, Beckman AU and Roche, respectively. For inter-laboratory robust CVs, no obvious differences were observed between each peer group. Conclusions The commutable ETV materials assigned via reference methods can evaluate the accuracy and reproducibility of an individual laboratory and the calibration traceability and uniformity between laboratories for measurements.

Funder

National Key Technology R&D Program of China

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference30 articles.

1. Burtis, CA, Ashwood, ER, Bruns, DE, editors. Fundamentals of clinical chemistry, 6th ed. St. Louis, MO: Saunders; 2007:432 p.

2. Scott, MG, LeGrys, VA. Electrolytes and blood gases. In: Burtis, CA, Ashwood, ER, Bruns, DE, editors. Tietz fundamentals of clinical chemistry, 6th ed. Missouri: Saunders Press; 2008:431–5 pp.

3. Brady, H, Ryan, M, Horgan, J. Magnesium: the forgotten cation. Ir Med J 1987;80:250–3. 3312087.

4. Gowenlock, AH, McMurray, JR, McLauchlan, DH, editors. Varley’s practical clinical biochemistry, 6th ed. London: Heinemann Medical Books; 1988.

5. Belk, WP, Sunderman, FW. A survey of the accuracy of chemical analyses in clinical laboratories. Am J Clin Pathol 1947;17:853–61. https://doi.org/10.1093/ajcp/17.11.853.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3