(Pre)analytical considerations concerning the analysis of synovial calprotectin

Author:

Alkadhem Mohammed F.1ORCID,Wagenmakers-Huizenga Lucie M.F.1,Wouthuyzen-Bakker Marjan2,Muller Kobold Anneke C.1ORCID

Affiliation:

1. Department of Laboratory Medicine , University of Groningen, University Medical Center Groningen , Groningen , The Netherlands

2. Department of Medical Microbiology and Infection Prevention , University of Groningen, University Medical Center Groningen , Groningen , The Netherlands

Abstract

Abstract Objectives Several studies have demonstrated that synovial calprotectin is a highly accurate biomarker in diagnosing periprosthetic joint infections (PJI). Assuring reliability is of great importance and coincides with adequate preanalytical handling. This study focuses on potentially interfering factors. Methods To assess the stability of synovial calprotectin, the effect of time, storage temperature, EDTA, freeze-thaw cycles, viscosity, and blood and lipid contamination was investigated. In the blood and lipid contamination experiments, hemolyzed and non-hemolyzed blood, homogenized adipose tissue, intralipid and chylomicrons were added. The effect of viscosity was investigated using freeze-thaw cycles, enzymatic pretreatment and sonification. Results No effect on synovial calprotectin levels was observed in synovial samples kept at room temperature compared to samples kept at 4 °C for up to seven days of storage. Freeze-thaw cycles did not result in significantly different calprotectin levels, although samples without EDTA resulted in higher recoveries after 1 and 2 freeze-thaw cycles. Blood and lipid contamination did not interfere with accurate synovial calprotectin analysis. Sample pretreatment to reduce sample viscosity by pretreating samples with DNAse and/or hyaluronidase did not influence calprotectin analysis. Sonification, however, resulted in increased calprotectin values. Conclusions Synovial calprotectin is a stable biomarker and its analysis is not easily influenced by potential interfering factors.

Funder

Universitair Medisch Centrum Groningen

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3