Biological variation of serum neurofilament light chain

Author:

Hviid Claus Vinter Bødker12,Madsen Anne Tranberg3ORCID,Winther-Larsen Anne1

Affiliation:

1. Department of Clinical Biochemistry , Aarhus University Hospital , Aarhus , Denmark

2. Department of Clinical Biochemistry , Horsens Regional Hospital , Horsens , Denmark

3. Department of Microbiology and Immunology , Albert Einstein College of Medicine , New York , NY , USA

Abstract

Abstract Objectives The neurofilament light chain (NfL) has emerged as a versatile biomarker for CNS-diseases and is approaching clinical use. The observed changes in NfL levels are frequently of limited magnitude and in order to make clinical decisions based on NfL measurements, it is essential that biological variation is not confused with clinically relevant changes. The present study was designed to evaluate the biological variation of serum NfL. Methods Apparently healthy individuals (n=33) were submitted to blood draws for three days in a row. On the second day, blood draws were performed every third hour for 12 h. NfL was quantified in serum using the Simoa™ HD-1 platform. The within-subject variation (CVI) and between-subject variation (CVG) were calculated using linear mixed-effects models. Results The overall median value of NfL was 6.3 pg/mL (range 2.1–19.1). The CVI was 3.1% and the CVG was 35.6%. An increase in two serial measurements had to exceed 24.3% to be classified as significant at the 95% confidence level. Serum NfL levels remained stable during the day (p=0.40), whereas a minute variation (6.0–6.6 pg/mL) was observed from day-to-day (p=0.02). Conclusions Serum NfL is subject to tight homeostatic regulation with none or neglectable semidiurnal and day-to-day variation, but considerable between-subject variation exists. This emphasizes serum NfL as a well-suited biomarker for disease monitoring, but warrants caution when interpreting NfL levels in relation to reference intervals in a diagnosis setting. Furthermore, NfL’s tight regulation requires that the analytical variation is kept at a minimum.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3