The new IVD Regulation 2017/746: a case study at a large university hospital laboratory in Belgium demonstrates the need for clarification on the degrees of freedom laboratories have to use lab-developed tests to improve patient care

Author:

Vermeersch Pieter.12,Van Aelst Tobias3,Dequeker Elisabeth M.C.34

Affiliation:

1. Clinical Department of Laboratory Medicine , University Hospitals Leuven , Leuven , Belgium

2. Department of Cardiovascular Sciences , KU Leuven , Leuven , Belgium

3. Biomedical Quality Assurance Research Unit, Department of Public Health and Primary Care , KU Leuven , Leuven , Belgium

4. Department of Medical Diagnostics , University Hospitals Leuven , Leuven , Belgium

Abstract

Abstract Objectives The new European In Vitro Diagnostic (IVD) Regulation 2017/746 (IVDR) restricts the use of lab-developed tests (LDT) after 26th May 2022. There are no data on the impact of the IVDR on laboratories in the European Union. Methods Laboratory tests performed in UZ Leuven were divided in four groups: core laboratory, immunology, special chemistry, and molecular microbiology testing. Each test was classified as Conformité Européenne (CE)-IVD, modified/off-label CE-IVD, commercial Research Use Only (RUO) or LDT. Each matrix was considered a separate test. Results We found that 97.6% of the more than 11.5 million results/year were generated with a CE-IVD method. Of the 922 different laboratory tests, however, only 41.8% were CE-IVD, 10.8% modified/off-label CE-IVD, 0.3% RUO, and 47.1% LDT. Off-label CE-IVD was mainly used to test alternative matrices not covered by the claim of the manufacturer (e.g., pleural or peritoneal fluid). LDTs were mainly used for special chemistry, flow cytometry, and molecular testing. Excluding flow cytometry, the main reasons for the use of 377 LDTs were lack of a CE-IVD method (71.9%), analytical requirements (14.3%), and the fact the LDT was in use before CE-IVD available (11.9%). Conclusions While the large majority of results (97.6%) were generated with a CE-IVD method, only 41.8% of laboratory tests were CE-IVD. There is currently no alternative on the market for 71.5% of the 537 LDTs performed in our laboratory which do not fall within the scope of the current IVD directive (IVDD). Compliance with the IVDR will require a major investment of time and effort.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference7 articles.

1. Regulation (EU). 2017/746 of the European Parliament and of the Council of 5 April 2017 on in vitro diagnostic medical devices and repealing directive 98/79/EC and Commission Decision 2010/227/EU. Available from: https://eur-lex.europa.eu/eli/reg/2017/746/oj.

2. Moan, B, Rabin, N. In vitro medical devices: how businesses can successfully comply with the new European regulation. Ann Biol Clin 2018;76:716–18. https://doi.org/10.1684/abc.2018.1369.

3. van Drongelen, A, de Bruijn, A, Pennings, J, van der Maaden, T. The impact of the new European IVD classification rules on the notified body involvement. A study on the IVDs registered in the Netherlands. RIVM Letter report 2018-0082.

4. Seger, C, Salzmann, L. After another decade: LC-MS/MS became routine in clinical diagnostics. Clin Biochem 2020 Mar 15, https://doi.org/10.1016/j.clinbiochem.2020.03.004 [Epub ahead of print].

5. Corman, V, Landt, O, Kaiser, M, Molenkamp, R, Meijer, A, Chu, DKW, et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill 2020;25:2000045. https://doi.org/10.2807/1560-7917.ES.2020.25.3.2000045.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3