Serous body fluid evaluation using the new automated haematology analyser Mindray BC-6800Plus

Author:

Boldú Laura1ORCID,Laguna Javier1ORCID,Casanova Alexandra1,García Saray1,Molina Angel1,Merino Anna1

Affiliation:

1. Haematology and Cytology Unit. CORE Laboratory. Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Centre , Hospital Clinic of Barcelona-IDIBAPS , Barcelona , Spain

Abstract

Abstract Objectives Cellular analysis of body fluids (BF) has clinical relevance in several medical conditions. The objective of this study is twofold: (1) evaluate the analytical performance of the BF mode of Mindray BC-6800 Plus compared to manual counts under microscopy and (2) analyse if the high-fluorescent cell counts provided by the analyser (HF-BF) are useful to detect malignancy. Methods A total of 285 BF was analysed: 250 corresponding to patients without neoplasia and 35 to patients with malignant diseases. Manual differential counts were performed in BF with ≥250 cells/μL. Percentages and absolute counts were obtained on the BC-6800Plus for total nucleated cells (TC-BF), mononuclear, polymorphonuclear and HF-BF. Statistical analysis was performed using Mann-Whitney U-test, Spearman’s correlation, Passing-Bablok regression, Bland-Altman graph and ROC curve. Results To compare manual and automatic total cell counts, samples were divided in three groups: <250, 250–1,000 and >1,000 cells/μL. Correlation was good in all cases (r=0.72, 0.73 and 0.92, respectively) without significant differences between both methods (p=0.65, 0.39 and 0.30, respectively). The concordance between methods showed values of 90%. Considering malignant samples, median HF-BF values showed significant higher values (102 cells/μL) with respect to non-malignant (4 cells/μL) (p<0.001). The cut-off value of 8.5 HF-BF/μL was able to discriminate samples containing malignant cells showing sensitivity and specificity values of 89 and 71%, respectively. Considering both, HF-BF and TC-BF values, sensitivity and specificity values were 100 and 53%, respectively. Conclusions This study reveals that the Mindray BC-6800Plus offers an accurate and acceptable performance, showing results consistent with the manual method. It is recommended to consider both HF-BF and TC-BF values for the screening of the microscopic evaluation to ensure the detection of all malignant samples.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3