Description and validation of an equilibrium dialysis ID-LC-MS/MS candidate reference measurement procedure for free thyroxine in human serum

Author:

Jansen Heleen I.123ORCID,van der Steen Rob4,Brandt André4,Olthaar André J.4,Vesper Hubert W.5,Shimizu Eri6,Heijboer Annemieke C.1237,Van Uytfanghe Katleen8,van Herwaarden Antonius E.4

Affiliation:

1. Department of Clinical Chemistry, Endocrine Laboratory , Amsterdam UMC Location Vrije Universiteit Amsterdam , Amsterdam , The Netherlands

2. Department of Clinical Chemistry, Endocrine Laboratory , Amsterdam UMC Location University of Amsterdam , Amsterdam , The Netherlands

3. Amsterdam Gastroenterology Endocrinology & Metabolism , Amsterdam , The Netherlands

4. Department of Laboratory Medicine , Radboud University Medical Center , Nijmegen , The Netherlands

5. Division of Laboratory Sciences , Centers for Disease Control and Prevention , Atlanta , GA , USA

6. Reference Material Institute for Clinical Chemistry Standards , Yokohama , Kanagawa , Japan

7. Amsterdam Reproduction & Development Research Institute , Amsterdam , The Netherlands

8. Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Laboratory of Toxicology , Ref4U, Ghent University , Ghent , Belgium

Abstract

Abstract Objectives Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. Methods This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. Results It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. Conclusions Our candidate cRMP measures FT4 accurately and performs well in serum matrix.

Funder

Landelijke Werkgroep Bindingsanalyse

Dutch Foundation of Quality Assessment in Medical Laboratories

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3