The effect of ratios upon improving patient-based real-time quality control (PBRTQC) performance

Author:

Li Yuanyuan123,Chen Xiaoling123,Zhao Ying123

Affiliation:

1. Department of Laboratory Medicine , The First Affiliated Hospital, Zhejiang University School of Medicine , Hangzhou , P.R. China

2. Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province , Hangzhou , P.R. China

3. Institute of Laboratory Medicine , Zhejiang University , Hangzhou , P.R. China

Abstract

Abstract Objectives Large biological variation hinders application of patient-based real-time quality control (PBRTQC). The effect of analyte ratios on the ability of PBRTQC to improve error detection was investigated. Methods Four single analyte-ratio pairs (alanine aminotransferase [ALT] vs. ALT to aspartate aminotransferase ratio [RALT]; creatinine [Cr] vs. Cr to cystatin C ratio [RCr]; lactate dehydrogenase [LDH] vs. LDH to hydroxybutyrate dehydrogenase ratio [RLDH]; total bilirubin [TB] vs. TB to direct bilirubin ratio [RTB]) were chosen for comparison. Various procedures, including four conventional algorithms (moving average [MA], moving median [MM], exponentially weighted moving average [EWMA] and moving standard deviation [MSD]) were assessed. A new algorithm that monitors the number of defect reports per analytical run (NDR) was also evaluated. Results When a single analyte and calculated ratio used the same PBRTQC parameters, fewer samples were needed to detect systematic errors (SE) by taking ratios (p<0.05). Application of ratios in MA, MM and EWMA significantly enhanced their ability to detect SE. The influence of ratio on random error (RE) detection depended upon the analytes and PBRTQC parameters, as consistent advantage was not demonstrated. The NDR method performed well when appropriate parameters were used, but was only effective for unilateral SE. Rearrangement of sample order led to a significant deterioration of conventional algorithms’ performance, while NDR remained almost unaffected. Conclusions For analytes with large variation and poor PBRTQC performance, using ratios as PBRTQC indexes may significantly improve performance and achieve better anti-interference ability, providing a new class of monitoring indicators for PBRTQC.

Funder

Natural Science Foundation of China of Zhejiang Province

National Key Technologies R&D Program, Ministry of Science and Technology of the People's Republic of China

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3