Multiple ECG segments denoising autoencoder model

Author:

Samann Fars12ORCID,Schanze Thomas1

Affiliation:

1. FB Life Science Engineering (LSE) , Technische Hochschule Mittelhessen (THM), Institut für Biomedizinische Technik (IBMT) Gießen , Germany

2. Department of Biomedical Engineering , University of Duhok , Duhok , Kurdistan Region , Iraq

Abstract

Abstract Objectives Denoising autoencoder (DAE) with a single hidden layer of neurons can recode a signal, i.e., converting the original signal into a noise-reduced signal. The DAE approach has shown a good performance in denoising bio-signals, like electrocardiograms (ECG). In this paper, we study the effect of correlated, uncorrelated and jittered datasets on the performance of the DAE model. Methods Vectors of multiple concatenated ECG segments of simultaneously recorded Einthoven recordings I, II, III are considered to establish the following dataset cases: (1) correlated, (2) uncorrelated, and (3) jittered. We consider our previous work in finding the optimal number of hidden neurons receiving the input signal with respect to signal quality and computational burden by applying Akaike’s information criterion. To evaluate DAE, these datasets are corrupted with six types of noise, namely mix noise (MX), motion artifact noise (MA), electrode movement (EM), baseline wander (BW), Gaussian white noise (GWN) and high-frequency noise (HFN), to simulate real case scenario. Spectral analysis is used to study the effects of noise whose power spectrum may overlap with the power spectrum of the wanted signal on DAE performance. Results The simulation results show (a) that the number of hidden neurons to denoise multiple correlated ECG is much lower than for jittered signals, (b) QRS-complex based ECG alignment preferable, (c) noises with slightly overlapping power spectrum, like BW and HFN, can be easily removed with sufficient number of neurons, while the noise with completely overlapping spectrum, like GWN, requires a very low-dimensional and thus coarser reduction to recover the signal. Conclusions The performance of DAE model in terms of signal-to-noise ratio improvement and the required number of hidden neurons can be improved by utilizing the correlation among simultaneous Einthoven I, II, III records.

Funder

Deutscher Akademischer Austauschdienst

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3