Learning curves for high tibial osteotomy using patient-specific instrumentation: a case control study

Author:

Stimolo Davide12ORCID,Leggieri Filippo1,Matassi Fabrizio1,Barra Angelo3,Civinini Roberto1,Innocenti Matteo12

Affiliation:

1. Department of Orthopaedics, AOU Careggi Florence , 60222 University of Florence , Florence , Italy

2. University of Florence, School of Human Health Sciences , Largo Brambilla 3, 50134 Florence , Italy

3. Department of Technical Professions and Rehabilitation , AOU Careggi Florence , Florence , Italy

Abstract

Abstract Objectives Three-dimensional (3D) planning and Patient Specific Instrumentation (PSI) can help the surgeon to obtain more predictable results in Medial Opening Wedge High Tibial Osteotomy (mOW-HTO) than the conventional techniques. We compared the accuracy of the PSI and standard techniques and measured the learning curve for surgery time and number of fluoroscopic shots. Methods We included the first 12 consecutive cases of mOW-HTO performed with 3D planning and PSI cutting guides and the first 12 non-supervised mOW-HTO performed with the standard technique. We recorded surgery time and fluoroscopic time. We calculated the variation (Δ delta) between the planned target and the postoperative result for Hip Knee Ankle Angle (HKA), mechanical medial Proximal Tibia Angle (MPTA), Joint Line Convergence Angle (JLCA) and tibial slope (TS) and compared it both groups. We also recorded the complication rate. We then calculated the learning curves for surgery time, number of fluoroscopic shots, Δ from target in both groups. CUSUM analysis charts for learning curves were applied between the two groups. Results Mean surgical time and mean number of fluoroscopic shots were lower in PSI group (48.58±7.87 vs. 58.75±6.86 min; p=0.034 and 10.75±3.93 vs. 18.16±4.93 shots; p<0.001). The postoperative ΔHKA was 0.42±0.51° in PSI vs. 1.25±0.87° in conventional, p=0.005. ΔMPTA was 0.50±0.67° in PSI vs. 3.75±1.48° in conventional, p<0.001; ΔTS was 1.00±0.82° in PSI vs. 3.50±1.57° in conventional, p<0.001. ΔJLCA was 1.83±1.11° in PSI vs. 4±1.41° in conventional, p<0.001. The CUSUM analysis favoured PSI group regarding surgery time (p=0.034) and number of shots (p<0.001) with no learning curve effect for ΔHKA, ΔMPTA, ΔJLCA and ΔTS. Conclusions PSI cutting guides and 3D planning for HTO are effective in reducing the learning curves for operation time and number of fluoroscopic shots. Accuracy of the procedure has been elevated since the first cases.

Publisher

Walter de Gruyter GmbH

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3