Abstract

AbstractStudies on the assessment of indoor air pollutants in terms of concentration and characterization in the Gulf Cooperation Council (GCC) countries have been recently carried out. This review assesses the health effects associated with indoor air pollution exposures in GCC, including other air pollutants (siloxanes, flame retardants, synthetic phenolic antioxidants) which were not explored in a previous study. In addition, the influence of ventilation conditions due to different indoor environments was also investigated. It was revealed that there is a lack of human health assessment studies on most indoor air pollutants in almost all GCC countries, except the United Arab Emirates, Kingdom of Saudi Arabia and Kuwait, where few attempts were made for some specific pollutants. Commonly reported plausible health effects potentially associated with indoor air pollution were related to respiratory symptoms and sick building syndrome (SBS). Many of the current health assessment studies in GCC countries were based on predictions and/or estimates of exposures rather than clinically based observational studies. Measured ventilation levels and indoor air velocities in most buildings failed to meet the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) threshold limits of 8 L/s/p and 0.18–0.25 m/s, respectively. Additionally, limited studies have investigated respiratory symptoms and SBS potentially attributable to poor ventilation in the region. It is highly recommended that future indoor air quality (IAQ) studies in GCC should focus more on epidemiologic and intervention studies.

Publisher

Walter de Gruyter GmbH

Subject

Public Health, Environmental and Occupational Health,Pollution,Health (social science)

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3