Comparison of plan quality and robustness using VMAT and IMRT for breast cancer

Author:

Yin Chuou1,Deng Juan1,Mei Guojian1,Cheng Hao1,He Yingying1,Liu Jiang1

Affiliation:

1. Department of Oncology, Deyang People’s Hospital , Deyang 618000 , China

Abstract

Abstract To evaluate the plan quality and robustness of volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) for breast cancer, 50 patients, including 25 patients who received radiotherapy after breast-conserving surgery (BCR) and 25 patients who received postmastectomy radiotherapy (PRT), were selected for this study. Nominal VMAT and IMRT plans were generated for each patient on Eclipse treatment planning system (version 15.6). The dosimetric metrics, dose distribution, gamma passing rate, and delivery time were compared. In addition, 12 uncertainty plans with plan isocenter uncertainty and CT density uncertainty were recalculated based on the nominal plans for each patient. The dose volume histogram (DVH) band width (DVHBW) was adopted to quantify the plan robustness of the nominal plans for the perturbed scenarios in this study. For BCR, the dosimetric metrics except planning target volume (PTV) conformal index (CI) and ipsilateral lung V 5 were not statistically different for IMRT and VMAT plans. PTV CI of VMAT plans was better than that of IMRT plans (VMAT: 0.923 ± 0.024, IMRT: 0.855 ± 0.032, p = 0.003). The ipsilateral lung V 5 of VMAT plan was higher than that of IMRT plan (VMAT: 42.4% ± 2.8%, IMRT: 40.5% ± 4.0%, p = 0.045). The VMAT plans save more than 1.20 min compared to the IMRT plans (VMAT: 0.87 min, IMRT: 2.08 min, p < 0.001). The gamma passing rates of VMAT plans were better than those of IMRT plans (3 mm/3%, VMAT: 99.7% ± 0.2%, IMRT: 99.4% ± 0.4%, p < 0.001; 2 mm/2%, VMAT: 97.2% ± 1.0%, IMRT: 96.9% ± 0.6%, p = 0.108). For PRT, the dosimetric metrics of VMAT plans, including PTV D mean, homogeneity index (HI), CI, and D max of spinal cord, were significantly better than those of IMRT plans. The VMAT plans save more than 45% time compared with IMRT plans (VMAT: 1.54 min, IMRT: 2.81 min, p < 0.001). The difference in gamma passing rates between VMAT plans and IMRT plans was not statistically significant. For the plan robustness, the DVHBW of VMAT plans and IMRT plans for BCR were 2.09% ± 0.23% and 2.98% ± 0.40%, respectively (p < 0.05). For PRT, the DVHBW of VMAT plans was significantly better than those of IMRT plans (VMAT: 3.05% ± 0.26%, IMRT: 3.57% ± 0.27%, p < 0.05). The results show that the dosimetric metrics of VMAT plans were comparable to those of IMRT plans. More importantly, the VMAT plans had excited dose distribution and fast execution efficiency. The plan robustness of VMAT plans were superior.

Publisher

Walter de Gruyter GmbH

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3