CHIPOFIL: A pilot study assessing the feasibility of HIPEC without extracorporeal circuit

Author:

Ortega-Deballon Pablo12,Facy Olivier3,Binquet Christine4,Delroeux Delphine5,Rat Patrick3

Affiliation:

1. Digestive Surgical Oncology, Equipe Avenir, 14 rue Paul Gaffarel, Dijon21079, France

2. Service de Chirurgie Digestive et Cancérologique, CHU Bocage Central, 14, rue Paul Gaffarel, Dijon Cedex21079, France

3. Digestive Surgical Oncology, University Hospital of Dijon, Dijon, France

4. CIC Epidémiologie Clinique, INSERM CR 1231, Dijon, France

5. Digestive Surgical Oncology, University Hospital of Besançon, Besançon, France

Abstract

AbstractBackgroundHeated intraperitoneal chemotherapy (HIPEC) is currently performed using an external circuit including a heating device and a pump. Available devices have several drawbacks in terms of costs, technique (flow surges due to blocked tubes) and staff safety, hindering a wider use. In a previous preclinical study conducted in animals, we placed a heating wire within the abdomen to achieve and maintain hyperthermia. Our results showed this technique is safe and effective. The present pilot study was conceived as the first use of such a device in humans, aiming to confirm its safety and efficacy.MethodsThis was a pilot study designed to include 13 patients undergoing HIPEC. Two sets of the prototype were placed within the abdominal cavity, one in the supramesocolic and one in the inframesocolic space. The target temperature was 42–43 °C during 30–90 min according to the protocol defined for each patient. The time to set up, heat and dismantle was measured. All complications were recorded during the first postoperative year and evaluated by an independent committee.ResultsNine women and four men were included. The median time to set on the device was 25 min. The target temperature was obtained in a median of 14 min and maintained uniform and homogeneously distributed within the abdomen for the scheduled duration. A permanent stirring of the viscera was performed. No thermal injury or device-related complications were observed. There were two anastomotic leaks (only one requiring reoperation), two hemoperitoneum requiring reoperation, one evisceration and one gastroparesia.ConclusionsA heating cable within the peritoneal cavity can achieve safe, simple, fast and efficient HIPEC.

Publisher

Walter de Gruyter GmbH

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3