Evaluation of the clinical chemistry tests analytical performance by using different models and specifications

Author:

Keleş MuratORCID

Abstract

Abstract Background The importance of managing analytical quality in clinical laboratories is known. Goal-setting models are critical for analytical quality management, along with correctly implemented error models. However, the methods used to determine analytical performance and more importantly, the relevant analytical quality goals are open to discussion. Our aim was to compare the analytical performance characteristics of routine clinical chemistry tests with different goal-setting models which was proposed by various establishments. In addition, to provide a perspective to Turkish total analytical error (TAE) circular letter that compulsory to calculate from 2016. Materials and methods This study was performed by the data obtained from the internal and external quality control of clinical chemistry tests which were measured by Roche Cobas c501 biochemistry analyzer. TAE calculated with TAE% = 1.65 ×(CV%) + Bias% formula. Nordtest uncertainty model was used in the calculation of measurement uncertainty (MU). In this context, total analytical error was evaluated with biological variation (BV), RCPA, CLIA and Turkish allowable total error (ATE) goals. Measurement uncertainty was evaluated with only permissible measurement uncertainty (pU%) goal. Results In our study, RCPA goals are the most stringent, followed by the BVEuBIVAS, BVRicos, pU%, CLIA and finally the ATETurkey goals coming in last. In cumulatively, BVEuBIVAS goals were 18.3% lower than BVRicos for evaluated parameters. Conclusion The balance between applicability and analytical assurance of goals should be well ensured when determining goal-setting models. Circular letter (2016/18) creates awareness to the analytical quality management but still open to development. Biological variation dependent total allowable error model never designed to be used as benchmarks for measurement uncertainty and it is not methodologically appropriate for assessing measurement uncertainty which was estimated by the Nordtest method. Also considered that, the use of “permissible MU” is more methodologically appropriate in the evaluation of measurement uncertainty.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,Molecular Biology,Biochemistry

Reference40 articles.

1. ‘Allowable Limits of Performance’ for External Quality Assurance Programs – an Approach to Application of the Stockholm Criteria by the RCPA Quality Assurance Programs;Clin Biochem Rev,2012

2. ‘Allowable Limits of Performance’ for External Quality Assurance Programs – an Approach to Application of the Stockholm Criteria by the RCPA Quality Assurance Programs;Clin Biochem Rev,2012

3. Biological and analytic components of variation in long-term studies of serum constituents in normal subjects. III. Physiological and medial implications;Clin Chem,1970

4. Quality goals in external quality assessment are best based on biology;Scand J Clin Lab Invest,1993

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3