Metrology for drug delivery

Author:

Lucas Peter,Klein Stephan

Abstract

AbstractIn various recently published studies, it is argued that there are underestimated risks with infusion technology, i.e., adverse incidents believed to be caused by inadequate administration of the drugs. This is particularly the case for applications involving very low-flow rates, i.e., <1 ml/h and applications involving drug delivery by means of multiple pumps. The risks in infusing are caused by a lack of awareness, incompletely understood properties of the complete drug delivery system and a lack of a proper metrological infrastructure for low-flow rates. Technical challenges such as these were the reason a European research project “Metrology for Drug Delivery” was started in 2011. In this special issue of

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference20 articles.

1. Capes Fluctuations in syringe - pump infusions : association with blood pressure variations in infants;Kimble;Am Health Syst Pharm,1995

2. Franken Risk profile infusion technology ( original title Infusietechnologie Kwaliteitsdocument van de Nederlandse Vereniging voor Klinische Technical report;Vaartjes,2008

3. Approaches for drug delivery with intracortical probes;Spieth;Biomed Tech,2014

4. Multi - infusion multiple problems validation and application of a system based on spectral - photometry for measuring fluid dynamics of multi - infusion systems in neonatal intensive care units Unpublished thesis University of;Riphagen;Development,2009

5. Benefits and risks of using smart pumps to reduce medication error rates : a systematic;Ohashi;review Drug,2014

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Relaxation times and dynamic behavior of an optofluidic flow meter in the nanoliter per minute regime;Physics of Fluids;2024-02-01

2. Medical flow and dosing measurement metrology in drug delivery;Biomedical Engineering / Biomedizinische Technik;2022-12-26

3. Assessment of drug delivery devices working at microflow rates;Biomedical Engineering / Biomedizinische Technik;2022-11-23

4. Metrology in health: challenges and solutions in infusion therapy and diagnostics;Biomedical Engineering / Biomedizinische Technik;2022-11-10