Adhesive strength of total knee endoprostheses to bone cement – analysis of metallic and ceramic femoral components under worst-case conditions

Author:

Bergschmidt Philipp,Dammer Rebecca,Zietz Carmen,Finze Susanne,Mittelmeier Wolfram,Bader Rainer

Abstract

Abstract Evaluation of the adhesive strength of femoral components to the bone cement is a relevant parameter for predicting implant safety. In the present experimental study, three types of cemented femoral components (metallic, ceramic and silica/silane-layered ceramic) of the bicondylar Multigen Plus knee system, implanted on composite femora were analysed. A pull-off test with the femoral components was performed after different load and several cementing conditions (four groups and n=3 components of each metallic, ceramic and silica/silane-layered ceramic in each group). Pull-off forces were comparable for the metallic and the silica/silane-layered ceramic femoral components (mean 4769 N and 4298 N) under standard test condition, whereas uncoated ceramic femoral components showed reduced pull-off forces (mean 2322 N). Loading under worst-case conditions led to decreased adhesive strength by loosening of the interface implant and bone cement using uncoated metallic and ceramic femoral components, respectively. Silica/silane-coated ceramic components were stably fixed even under worst-case conditions. Loading under high flexion angles can induce interfacial tensile stress, which could promote early implant loosening. In conclusion, a silica/silane-coating layer on the femoral component increased their adhesive strength to bone cement. Thicker cement mantles (>2 mm) reduce adhesive strength of the femoral component and can increase the risk of cement break-off.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference68 articles.

1. Surface pretreatment of endoprostheses by silica/silane to optimise the hydrolytic stability between bone cement and metal. Total hip and knee arthroplasty;Orthopaede,2008

2. Alternative materials and solutions in total knee arthroplasty for patients with metal allergy;Orthopaede,2008

3. Mechanical validation of whole bone composite femur models;J Biomech,1996

4. Tribological aspects of ceramics in total hip and knee arthroplasty;Semin Arthroplasty,2011