Evaluation of a novel noninvasive continuous core temperature measurement system with a zero heat flux sensor using a manikin of the human body

Author:

Brandes Ivo F.,Perl Thorsten,Bauer Martin,Bräuer Anselm

Abstract

AbstractReliable continuous perioperative core temperature measurement is of major importance. The pulmonary artery catheter is currently the gold standard for measuring core temperature but is invasive and expensive. Using a manikin, we evaluated the new, noninvasive SpotOn™ temperature monitoring system (SOT). With a sensor placed on the lateral forehead, SOT uses zero heat flux technology to noninvasively measure core temperature; and because the forehead is devoid of thermoregulatory arteriovenous shunts, a piece of bone cement served as a model of the frontal bone in this study. Bias, limits of agreements, long-term measurement stability, and the lowest measurable temperature of the device were investigated. Bias and limits of agreement of the temperature data of two SOTs and of the thermistor placed on the manikin’s surface were calculated. Measurements obtained from SOTs were similar to thermistor values. The bias and limits of agreement lay within a predefined clinically acceptable range. Repeat measurements differed only slightly, and stayed stable for hours. Because of its temperature range, the SOT cannot be used to monitor temperatures below 28°C. In conclusion, the new SOT could provide a reliable, less invasive and cheaper alternative for measuring perioperative core temperature in routine clinical practice. Further clinical trials are needed to evaluate these results.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference84 articles.

1. Precision and accuracy of intraoperative temperature monitoring;Cork;Anesth Analg,1983

2. Perioperative normothermia to reduce the incidence of surgical - wound infection and shorten hospitalization Study of Wound Infection and Temperature Group;Kurz;Engl J Med,1996

3. DM Core temperature measurement in the intensive care unit;Nierman;Crit Care Med,1991

4. and evaluation of a manikin for perioperative heat exchange;Brauer;English Construction Acta,2002

5. Human thermal environments : the effects of hot moderate and cold environments on human health comfort and performance nd ed London New York xxiv;Parsons,2003