Affiliation:
1. Institut für Physikalische und Theoretische Chemie, Universität Tübingen
Abstract
A combined automatic set up for the measurement of fluorescence and absorbance is described. The absorbance at irradiation wavelength E' and a fluorescence reaction spectrum are measured continously and simultaneously. Even for solutions with high concentrations up to E'>1, the fluorescence intensity can be corrected for. By this method the photodegradation of fluorescent dyes was examined. Because only a few of the degradation products fluoresce, the determination of kinetic parameters is easier than from absorbance measurements. The method gave good results for laser dyes using even high concentrations (E'> 1), with less calculatory expenditure and smaller standard deviation in comparison to the evaluation of absorbance measurements only
Subject
Physical and Theoretical Chemistry,General Physics and Astronomy,Mathematical Physics
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. References;Photokinetics - Theoretical Fundamentals and Applications;1998
2. Experimental Techniques in Photokinetic Analysis;Photokinetics - Theoretical Fundamentals and Applications;1998
3. Correction of emission data in quenching experiments;Journal of Photochemistry;1982-01
4. Application of Derivative Spectroscopy to Photokinetics;Zeitschrift für Physikalische Chemie;1981-02-01