Affiliation:
1. Rzeszów University of Technology, Faculty of Civil and Environmental Engineering and Architecture, ul. Poznańska 2,35-084Rzeszów, Poland
Abstract
AbstractThe article presents comparative analyzes aimed at determining the optimal cross-section used in cold-formed steel purlins. The geometrical characteristics, bending resistance and self-weight of channel, zeta and hat cross-sections were compared. The calculations were made using Dlubal SHAPE-THIN software for the bending by the main axis y-y and z-z. The characteristics for the gross and effective cross-section were determined. Based on the first stage analyzes, a significant decrease in cross-sectional bending resistant was observed as a result of a local buckling. The solution to this problem may be the use of intermediate stiffeners. In the second stage, analysis of the impact of the intermediate stiffeners’ locations on the characteristics of hat sections were conducted. Additional intermediate stiffeners on the webs, on the upper chord, and on the webs and upper chord (together) were considered. A significant effect on the bending resistant with a small increase in the element’s self-weight has been demonstrated. In the third stage, the characteristics of a channel, zeta and hat profile with intermediate longitudinal stiffener in the middle of the web were compared. The performed analyzes demonstrated that the hat cross-section shows a significant advantage in bending by the main axis z-z. This advantage can be used in case of lack of protection against lateral torsional buckling and a larger degree of roof slope.
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Aerospace Engineering,General Materials Science,Civil and Structural Engineering,Environmental Engineering
Reference16 articles.
1. Computer Design of Cold-Formed C- and Z-Section Purlins;J Construct Steel Res,1998
2. Structural efficiency of cold-formed steel purlins;International Conference Knowledge-Based Organization,2015
3. Cold-Formed Steel Channel Sections with Web Stiffeners Subjected to Local and Distortional Buckling – Part I: Tests and Finite Elements Analysis;International Specialty Conference on Cold-Formed Steel Structures,2014
4. Experimental Investigation for Non and Partially Composite Cold-Formed Steel Floor Beams;Civil. Eng J (NY)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献