An implantable ISM band antenna for biomedical application

Author:

Bose Moumita12ORCID,Biswas Ashim Kumar3,Sarkhel Abhishek4,Kundu Aparna5,Chakraborty Ujjal1

Affiliation:

1. Department of Electronics and Communication Engineering , National Institute of Technology , Silchar , Assam , 788010 , India

2. Department of Electronics and Communication Engineering , NSHM Knowledge Campus , Durgapur , West Bengal , 713212 , India

3. Department of Electronics and Communication Engineering , JIS College of Engineering , Kalyani , Nadia , 741235 , India

4. Department of Electronics and Communication Engineering , National Institute of Technology , Shillong , Meghalaya , 793003 , India

5. Department of Electronics and Communication Engineering , DIATM , Durgapur , West Bengal , 713212 , India

Abstract

Abstract This article presents a compact implantable antenna for biomedical use in the ISM band (2.4–2.48 GHz). The antenna is designed with Roger RT/duroid 6010.2LM high permittivity substrate of thickness 0.25 mm, and feed with a 50 Ω co-axial feed. A hybrid-loop resonator slot structure and C & I-shaped slots in the radiating patch has enabled the antenna to work in the ISM band. Via less ground makes this design simple, easier to fabricate, and a suitable candidate for implantable application. The proposed antenna occupies a small volume of 0.0984 λ 0 × 0.082 λ 0 × 0.00468 λ 0 and retained 152 MHz bandwidth (2.4077–2.5599 GHz with FBW 7.64 %) with a maximum gain of −22 dBi where λ 0 is guided wavelength. The projected antenna has good performance in the multi-layer tissue model, male human head voxel model, frequency-dependent skin model, and in muscle phantom by maintaining a minimum −20 dB return-loss in the ISM band. The proposed antenna’s Device Integration using a frequency-dependent skin phantom was performed and the results are well-suited for biomedical applications in the ISM band. The bare antenna was used to study the Specific Absorption Rate (SAR) in the human scalp. Where for 1 g and 10 g tissues the investigated results are 626.05 W/kg and 84.4 W/kg for an input power of 1 W, however the input power is limited to maximum 2.55 mW (for 1 g tissue) and 23.56 mW (for 10 g tissue) to comply with IEEE SAR guidelines. The qualities of the manufactured antenna are verified in a skin-imitating gel and animal tissue that exhibits good agreement with the simulation outcomes.

Publisher

Walter de Gruyter GmbH

Subject

Electrical and Electronic Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3