A comparison study about the extraction and separation of Cu2+ and Ni2+ with Lix984N in a microchannel reactor and separating funnel has been conducted. The results showed that, in the microchannel reactor, the overall volumetric mass transfer coefficient of copper was 20 times that of nickel, whereas in the separating funnel, it was only 2 times that of nickel. In addition, the separation coefficient of copper and nickel in the microchannel reactor was 5 times that of the conventional one. Typically, at initial pH=2.5, contact time 1.95 s, volume fraction of extractant Lix984N 15% and within 1.9 g l−1 nickel ion concentration, the extraction rate of copper was higher than 95%, but the nickel was hardly extracted. In comparison, it needed almost 50 s to reach a Cu extraction of 95% in the separation funnel, with more than 5% Ni co-extraction rate. Although the microfluid extraction showed excellent extraction performance, there exists a need to further improve its processing capacity to apply it to industrial production. Furthermore, scaling up the microreactor has become increasingly promising under the fast developing 3D printing technology.