Stabilized sensing of heparin in whole blood using the ‘gate effect’ of heparin-imprinted polymer grafted onto an electrode

Author:

Yoshimi Yasuo,Inaba Ryo,Ogawa Takaya,Yoshino Waka,Inoue Masaru,Kuwana Katsuyuki

Abstract

AbstractA real-time heparin monitor is required to optimize the dosage of heparin and its antidote, protamine sulfate, during extracorporeal circulation procedures. The gate effect of molecularly imprinted polymer (MIP) is a potential tool for the rapid and selective sensing of heparin. We here present a method to stabilize the measurement of heparin concentration in whole blood using an MIP-grafted electrode. An initiator of radical polymerization, the diethyldithiocarbamicbenzyl group, was introduced onto the surface of an indium-tin oxide (ITO) electrode. Heparin sodium, methacryloxethyltrimethoxysilane, and acrylamide were dissolved in water, and methylenebisacrylamide was dissolved in dimethylformamide. A mixture of the two solutions was introduced into the 50 μm gap between the surfaces of a quartz crystal plate and the treated ITO electrode. Ultraviolet light was irradiated onto the surface of the ITO to graft the copolymer of the monomers, then the ITO was washed with a 1 M sodium chloride aqueous solution to remove the heparin template and obtain the MIP-grafted electrode. Cyclic voltammetry was performed with the MIP-grafted electrode in physiological saline or bovine whole blood containing 0-8 units/ mL heparin and 5 mM ferrocyanide as a redox marker, and the relationship between the current intensity and the heparin concentration was analyzed. The current intensity decreased as the heparin concentration in either saline or whole blood increased, and the sensitivity of the electrode to heparin in blood was approximately 52% of its sensitivity to heparin in saline. The grafted-electrode was washed with a protease-containing detergent (Sterizyme® S, Maruishi Pharmaceutical) between measurements in blood. The heparin-sensitivity of the washed electrode in blood was 77% of that in saline. No sensitivity to chondroitin sulfate C was observed but sensitivity to low molecular weight heparin was demonstrated. We thus conclude that selective and stable sensing of heparin can be achieved using an electrode grafted with heparinimprinted polymer.

Publisher

Portico

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3