Construct validity and reliability of tests for sacroiliac dysfunction: standing flexion test (STFT) and sitting flexion test (SIFT)

Author:

Ribeiro Rafael P.12ORCID,Guerrero Filipe G.2ORCID,Camargo Eduardo N.12ORCID,Pivotto Luiza R.3ORCID,Aimi Mateus A.3ORCID,Loss Jefferson F.3ORCID,Candotti Cláudia T.3ORCID

Affiliation:

1. School of Physical Education, Physiotherapy and Dance (ESEFID) , Brazilian Institute of Osteopathy (IBO), Federal University of Rio Grande do Sul (UFRGS) , Porto Alegre , Rio Grande do Sul , Brazil

2. Brazilian Institute of Osteopathy (IBO) , Porto Alegre , Rio Grande do Sul , Brazil

3. School of Physical Education, Physiotherapy and Dance (ESEFID) , Federal University of Rio Grande do Sul (UFRGS) , Porto Alegre , Rio Grande do Sul , Brazil

Abstract

Abstract Context Sacroiliac dysfunction is characterized by a hypomobility of the range of motion of the joint, followed by a positional change regarding the relationship between the sacrum and the iliac. In general, the clinical tests that evaluate the sacroiliac joint (SIJ) and its dysfunctions lack validity and reliability values. Objectives This article aims to evaluate the construct validity and intra- and inter-rater reliability of the standing flexion test (STFT) and sitting flexion test (SIFT). Methods In this prospective study, the sample consisted of 30 individuals of both sexes, and the evaluation team was composed of five researchers. The evaluations took place on two different days: first day, inter-rater reliability and construct validity; and second day, intra-rater reliability. The reference standard for the construct validity was 3-dimensional measurements obtained utilizing the BTS SMART-DX system. For statistical analysis, the percentage (%) agreement and the kappa statistic (K) were utilized. Results The construct validity was determined for STFT (70% agreement; K=0.49; p<0.01) and SIFT (56.7% agreement; K=0.29; p<0.05). The intra-rater reliability was determined for STFT (66.3% agreement; K=0.43; p<0.01) and SIFT (56.7% agreement; K=0.38; p<0.01). The inter-rater reliability was determined for STFT (10% agreement; K=−0.02; p=0.825) and SIFT (13.3% agreement; K=0.01; p=0.836). Conclusions The STFT confirmed the construct validity and was reliable when applied by the same rater to healthy people, even if the rater had no experience. It was not possible to achieve minimum scores using the SIFT either for construct validity or reliability. We suggest that further studies be conducted to investigate the measurement properties of palpatory clinical tests for SIJ mobility, especially in symptomatic patients.

Publisher

Walter de Gruyter GmbH

Subject

Complementary and alternative medicine,Complementary and Manual Therapy

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3