Author:
Dojka M.,Dojka R.,Studnicki A.
Abstract
Abstract
The aim of presented studies was to develop a new geometry of the overflow part of standard ATD-C tester for derivative thermal analysis in a way that it would allow to obtain samples for abrasion and mechanical properties tests in the same mould without the need of cutting them from a block of material. The pattern of new ATD-P tester has parts reflecting implemented samples. Computer simulations regarding initial verification of new tester were performed in NovaFlow software. Chromium cast iron melts were made for testing the sampler in real conditions and TDA analysis for casting material were conducted. The sandmix was prepared on silica sand matrix per the ALPHASET technology. This new solution greatly simplifies the preparations of materials difficult to machine.
Subject
Metals and Alloys,Industrial and Manufacturing Engineering
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献