Research on dual-mode fault suppression strategy of AC isolation and current limiting based on hybrid MMC
Author:
Liu Yujia1ORCID, He Baina1ORCID, Bian Chenxi1ORCID, Lin Xin2, Liu Yang1, Wu Shuo1, Meng Fantao1, Lou Hui1, Kong Lingzhe1, Dai Xueting1
Affiliation:
1. College of Electric and Electronic Engineering , Shandong University of Technology , Shandong Zibo , 255000 , China 2. Key Laboratory of Special Machine and High Voltage Apparatus , Ministry of Education, Shenyang University of Technology , Shenyang , 110000 , China
Abstract
Abstract
The DC side fault of the high voltage DC transmission system based on modular multilevel converters high voltage DC (MMC-HVDC) is easily affected by the double influence of AC transient electrical quantity infeed and overvoltage and overcurrent, seriously threatening the safe operation of the power grid. Aiming at the problem above, a fault suppression strategy in dual mode of isolation and current limiting is proposed. Based on the half-bridge-full-bridge hybrid MMC, the fault transient mathematical model considering AC feed and sub-module switching feed is analyzed. AC isolation module with double conduction self-resistance structure and current-limiting control module is constructed, which can be adaptively adjusted to the system’s direct current parameters. The ±500 kV double-ended hybrid MMC system model is established to verify the scheme’s effectiveness. In addition, the influence of high AC modulation parameters on the suppression effect is investigated. PSCAD/EMTDC simulation results show that AC active and reactive power feed-in peaks are reduced by 388.69 MW and 119.82 Mvar, respectively, under dual-mode control. The peak value of DC overvoltage and overcurrent is reduced by 1211.53 kV and 22.5 kA, respectively, the fault self-clearing time is shortened by 43 ms, and the fault suppression effect is remarkable. In the high AC modulation ratio operating state, the modulation parameters are positively correlated with the AC power feed and negatively correlated with the overvoltage and overcurrent of the DC system. The research results provide support for the fault protection scheme of the hybrid MMC flexible and direct power grid.
Funder
Department of Education of Shandong Province Key Laboratory of Special Machine and High Voltage Apparatus Natural Science Foundation of Shandong Province
Publisher
Walter de Gruyter GmbH
Subject
Energy Engineering and Power Technology
Reference20 articles.
1. Jingru, Z, Baina, H, Rongxi, C, Xingmin, H, Yanchen, D. Novel adaptive reclosing scheme of MMC-HVDC transmission lines based on phase synchronization compensation control. IET Gener, Transm Distrib 2022;16:1836–48. 2. Andrés, M, Matías, U, Roberto, C, Alejandro, A, Mauricio, E, Matías, D, et al.. Model-predictive-control-based capacitor voltage balancing strategies for modular multilevel converters. IEEE Trans Ind Electron 2019;66:2432–43. 3. Yadi, X, Baina, H, Lemiao, W, Renzhuo, J, Yuyang, Z, Yazhe, M, et al.. Characteristics of secondary arc current on UHVDC and EHV AC transmission lines erected on the same tower. Int J Emerg Elec Power Syst 2019;20:1–14. 4. Jingru, Z, Baina, H, Renzhuo, J, Xingmin, H, Yanchen, D, Chenxi, B, et al.. Adaptive restart scheme based on active injection current ratio for half-bridge MMC-HVDC with overhead transmission lines. Int J Emerg Elec Power Syst 2021;22:353–67. 5. Taiyuan, Y, Yue, W, Guochao, D, Gang, L, Siquan, H. Zero DC voltage control based DC fault ride-through strategy for hybrid modular multilevel converter in HVDC. Trans China Electrotech Soc 2019;34:343–51.
|
|