Abstact The corona-generated electromagnetic field environment under and nearer to the extra high dc potential conductors generates an ill health environment which causes serious electrical threats to living organisms present in the conductor corridor. The ionized electromagnetic field environment is characterizing with ionized ionic current flow and enhanced electric field perturbation at ground levels. The primary factors which affect the safe and economical design dimensions of high potential dc conductors are conductor diameter, altitude, applied potential and atmospheric parameters such as temperature, humidity, pressure, and aerosol pollution, etc. This remains a challenging task to design the HVDC transmission system at extended potential levels, as HVDC system employed for a large amount of power transfer barrier in the electrical system to meet inevitable power thrust. To obtain a safe and economical design configuration, multiple experimental design measurements are essential at various climatic seasons which incorporates the tedious process and significant economical expenditure. To obtain the safe and cost-effective design dimension configuration, computational-based numerical analysis with final experimental validation offers substantial support. Using various computational methodologies, many researchers have attempted to guide the critical line design proportions to establish a safe and economical electrical environment beneath the lines at ground levels. All these computational techniques are emphasizing the algorithm iterative-based complex solutions claim the lack of computational accuracy. Hence, this work aims to provide a unique computational technique to analyse the ionised electromagnetic field environment of a unipolar UHV dc transmission system using modelling of the physics of the corona discharge procedure in the active high electrostatic field zone. Modelling of the corona discharge includes the estimation of the amount of new ionized ions generated in the ionization region dynamically claims complex less equations offer a unique solution. To validate the accuracy of the proposed computational technique, multiple outdoor experimental measurements are carried out at HV/EHV/UHV potential applications and discussed. Also, the computed results are compared with the experimental findings, from the comparison outstanding computational accuracy was marked.

Publisher

Walter de Gruyter GmbH

Subject

Energy Engineering and Power Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3