Evaluation of four different HPLC devices for hemoglobinopathy screening

Author:

Ercan Karadağ Müjgan1ORCID,Akbulut Emiş Deniz2,Avcı Esin3,Fırat Oğuz Esra2ORCID,Kader Saadet4ORCID,Abuşoğlu Gülsüm5ORCID,Serdar Muhittin6ORCID,Yılmaz Fatma Meriç2

Affiliation:

1. Department of Biochemistry, Faculty of Medicine , Harran University , Şanlıurfa , Turkey

2. Biochemistry Laboratory , Ankara City Hospital , Ankara , Turkey

3. Department of Biochemistry, Faculty of Medicine , Pamukkale University , Denizli , Turkey

4. Department of Biochemistry , Bilecik Public Health Laboratory , Bilecik , Turkey

5. Department of Medical Laboratory Techniques , Vocational School of Health , Konya , Turkey

6. Department of Biochemistry, Faculty of Medicine , Acıbadem University , İstanbul , Turkey

Abstract

Abstract Objective Hemoglobinopathies are a common public health problem in Turkey. In the screening of these disorders in population, cation-exchange high performance liquid chromatography (HPLC) is accepted as the gold standard method. In this study, the aim was to assess four different HPLC devices used in hemoglobinopathy screening. Materials and methods A total of 58 blood samples were analyzed with four different HPLC methods (Bio-Rad variant II, Agilent 1100, Tosoh G8 and Trinity Ultra2 trademarks). Results The comparison study demonstrated a good correlation between the results of each HPLC analyzer and the reference value obtained by averaging all the HbA2 results belonging to the methods tested in the study [ (Tosoh G8 (r=0.988), Bio-Rad variant II (r=0.993), Agilent 1100 (r=0.98) and Trinity Ultra2 (r=0.992) ]. HbA2 determination in the presence of HbE was interfered in both Bio-Rad variant II and Tosoh G8. Conclusion The analyzers were found to have compatible HbA2 results but with accompanying different degrees of proportional and systematic biases. HPLC analyzers may be affected by different hemoglobin variants at different HbA2 concentrations, which is an important point to take into consideration during the evaluation of HbA2 results in thalassemia screening.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,Molecular Biology,Biochemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3