Affiliation:
1. Department of Medical Biochemistry , Istanbul Gaziosmanpasa Taksim Education and Research Hospital , Istanbul , Turkey
2. Department of Physical Medicine and Rehabilitation , Istanbul Gaziosmanpasa Taksim Education and Research Hospital , Istanbul , Turkey
Abstract
AbstractBackgroundUnsuitable samples are common problem for laboratories. The blood collection tubes need to be validated or verified prior to their being used in the routine laboratory for reducing this situation.ObjectiveWe aim to compare the technical qualifications of routinely used BD Vacutainer®Serum Separator Tubes™ II Advance Plus with BD Vacutainer®Barricor™ LH Plasma Tubes for local technical validation.Materials and methodsApparently healthy 150 voluntary subjects were enrolled in the study. Samples were collected in two separated tubes by a single phlebotomist. Twelve quality indicators were used to compare these two different types of tubes for local technical validation. Differences (%) between them were calculated with the formula proposed by EFLM. In case of any difference of less than 1% for each indicator, the evaluated tube was considered as non-inferior.ResultsIndicators, such as tubes with physical defects, that fail to create vacuum, not properly fitting into the blood collection device, under filling (10%), cracked tubes, tubes exterior surface contaminated with blood, hemolysed specimens, including fibrin strand/mass in the sample, red blood cell adhesion, poor/incomplete barrier formation were found non-inferior in Barricor™ tubes. White particulate matter (WPM) was observed in 24.6% of Barricor™. Therefore, the last indicator (tubes including gel/foreign material/WPM in sample after centrifugation) was found inferior for Barricor™.ConclusionTechnical local validation studies should be encouraged in terms of quality management. It was thought that WPM would not cause any interference in a properly filled tube. In addition to, Barricor™ was also found to be technically acceptable when evaluated through using all other indicators.
Subject
Biochemistry (medical),Clinical Biochemistry,Molecular Biology,Biochemistry
Reference36 articles.
1. International Organization for Standardization. Quality management systems – fundamentals and vocabulary. ISO 9000:2005. Switzerland: ISO, Geneva, 2005.
2. CLSI. Validation and verification of tubes for venous and capillary blood specimen collection; approved guideline. CLSI document GP34-A. Wayne, PA: Clinical and Laboratory Standards Institute, 2010.
3. Schrapp A, Mory C, Duflot T, Pereira T, Imbert L, Lamoureux F. The right blood collection tube for therapeutic drug monitoring and toxicology screening procedures: standard tubes, gel or mechanical separator? Clin Chim Acta 2019;488:196–201.
4. Arslan FD, Karakoyun I, Basok BI, Aksit MZ, Baysoy A, Ozturk YK, et al. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor™ LH Plasma tube. Biochem Med (Zagreb) 2017;27:030706.
5. Lippi G, Cornes MP, Grankvist K, Nyboand M, Simundic AM. EFLM WG-Preanalytical phase opinion paper: local validation of blood collection tubes in clinical laboratories. Clin Chem Lab Med 2016;54:755–60.