Design and simulation of 30 000 tons per year of cumene plant from natural gas field

Author:

Ojong Ojong Elias1ORCID,Wosu Omeke Chimene2ORCID,Emenike Aguma3,Ubi Paschal Ateb4ORCID

Affiliation:

1. Chemical Engineering, Faculty of Engineering and Technology , University of Calabar , Calabar , Cross River State , Nigeria

2. Chemical Engineering Department, Faculty of Engineering , Federal University of Otuoke , Otuoke , Bayelsa State , Nigeria

3. Chemical/Petrochemical Engineering, Faculty of Engineering , Rivers State University , Nkpolu Oroworukwo Port Harcourt , Rivers State , Nigeria

4. Mechanical Engineering, Faculty of Engineering and Technology , University of Calabar , Calabar , Cross River State , Nigeria

Abstract

Abstract The research considers the design and simulation of 30 000 tons per year of cumene plant using Aspen HYSYS as the simulation tool. The feed (material content) used is the characterized natural gas from Utorogu Gas Field with composition of 0.9019 methane, 0.0694 ethane, 0.0209 propane, 0.00361 n-butane, 0.00414 i-butane, 0.00005 n-pentane and 0.00007 i-pentane. The cumene plant consist of the cryogenic distillation column, de-hydrogenator (Continuous Stirred Tank Reactor), Alkylator (Plug Flow Reactor), storage tanks, separators, pumps, heat exchanger and mixers. The size/design models of basic plant units such as de-hydrogenator, alkylator, separators, storage tanks and distillation column were developed using the principles of mass and energy balance. The result of design or size specifications in terms of equipment diameter of basic plant units obtained from HYSYS simulation are 0.8 m and 0.319 m for the cryogenic and cumene columns; 1.931 m, 2.244 m and 1.366 m for the propane, propene and cumene storage tanks; 1.868 m and 2.076 m for the de-hydrogenator and alkylator; 1.931 m and 2.146 m for propene and cumene separators respectively. The power or capacity of propane and propene pumps configured in the plant are 0.02 kW and 0.005 kW respectively. The result of the reactor and distillation column thickness specification to withstand corrosion, pressure or stress during plant operation in terms of cylindrical shell and ellipsoidal doomed head are 17.36 mm and 4.31 mm respectively. The economic evaluation (overall cost) including the cost of utilities, catalyst, operating, and maintenance for entire plant is $ 3.004 M.

Publisher

Walter de Gruyter GmbH

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3