On mass dynamics in a closed ecological system, determined with a prototype vacuum mass comparator – a methodological validation study

Author:

Lintzen Thomas1,Pabst Markus2ORCID,Fröhlich Thomas3ORCID

Affiliation:

1. Private , Große Weinmeisterstr., 29 , Potsdam , Germany

2. Prozessmesstechnik , Technische Universität Ilmenau Fakultät für Maschinenbau , Gustav-Kirchhoff-Str. 1 , Ilmenau , Germany

3. Institut für Prozessmess- und Sensortechnik , TU Ilmenau , PF 100 565, 98684 Ilmenau , Germany

Abstract

Abstract The aim of this work was to validate a novel methodology for high-resolution, repetitive measurements of mass dynamics of biological processes and structures in a closed plant-earth ecosystem consisting of Mammillaria vetula and microorganisms. To perform these experiments, the living system was materially welded into a newly developed Titanium Weighing Hollow Body (TWHB) with a laser. Three non-vital, also hermetically welded and high-vacuum suitable, externally identical TWHBs, filled with sand, served as controls. All TWHBs were equipped with a feedthrough and integrated light source. LEDs generated continuous light in all four bodies, which drove the photobiological processes in the vital test body and allowed long-term growth. Mass differences of the TWHBs were measured with a vacuum mass comparator at four points in time three months apart against two stainless steel mass standards. The expanded measurement uncertainty of the mass increase of the vital TWHB was calculated according to the Guide to the Expression of Uncertainty in Measurement (GUM) in each of the three independent experiments. The mass gain of the vital over the three nonvital TWHBs over the total experimental period of 9 months was +18 μg with the expanded measurement uncertainty 30 μg. The resulting mass gain would have had to be > 48 μ g $ > 48\enspace {\upmu }\mathrm{g}$ to be considered statistically significant with a confidence level of 97.7%; time intervals over three and six months were also not significant. The study validates for the first time a methodology capable of measuring mass dynamics of living matter over time, when statistically sound conclusions with measurement uncertainties in the microgram range are required. This opens up a new level of precision mass measurements, which makes the methodology a candidate, e.g., for the verification of the principle of mass conservation in the life-sciences.

Publisher

Walter de Gruyter GmbH

Subject

Electrical and Electronic Engineering,Instrumentation

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3